Canon imageRUNNER ADVANCE C5560i III User Manual page 1236

Hide thumbs Also See for imageRUNNER ADVANCE C5560i III:
Table of Contents

Advertisement

The test page with "1st side" printed on it is the front side.
2
On the <Adjust Image Position> screen, press <-> or <+> to adjust <Front Side> for
<Lead Edge Alignment> so that the center line of the register mark is aligned with
the edge of the paper.
In case of the example described above, set "0.4" for <Front Side>.
<+>
Press when the center line of the register mark is located outside the edge of the test page (the center line
of the register mark is NOT printed). The image is shifted to the backwards as seen from the feeding
direction of the paper, according to the entered value.
<->
Press when the center line of the register mark is located inside of the edge of the test page. The image is
shifted to the forwards as seen from the feeding direction of the paper, according to the entered value.
3
Turn over the test page
page.
4
Press <-> or <+> for <Back Side> in <Lead Edge Alignment> to input the value to shift
the image.
5
Perform the test page again, and check the image position
Repeat the correction again, if necessary.
When you open the <Adjust Image Position> screen again after you close that screen by pressing <OK>,
the values on screen are returned to <0>. However, the adjusted value is still effective. If you repeat steps,
read off the value of register marks from new test page and input the new value.
To restore the accumulated value, press <Restore Initial Settings>.
Maintenance
check the lead edge image on the back side of the test
1222
press <OK>.

Advertisement

Table of Contents
loading

Table of Contents