Concluding steps
▶
"Reassembling" on page
▶
"Connecting the power cord" on page
▶
"Switching on the server" on page
▶ If applicable,
"Installing the front cover with lock" on page
▶ Update the system information of your server using the Chassis ID Prom
Tool, see
"Using the Chassis ID Prom Tool" on page
corresponding system name.
▶
"Performing a RAID array rebuild" on page
7.7.3
Upgrading with rear HDD cage 2
Field Replaceable Unit
(FRU)
– Phillips PH2 / (+) No. 2 screw driver
Tools:
– Phillips PH1 / (+) No. 1 screw driver
CAUTION
All data on all HDDs/SSDs in the array will be lost when deleting the
RAID array!
▶
Be sure to back up your data before deleting a RAID array.
▶
For more information, see the "ServerView Suite RAID
Management" user guide.
After installing or removing an additional backplane, never forget to
change the system information using the Chassis ID Prom Tool.
Preliminary steps
▶ If applicable,
"Removing the front cover with lock" on page
▶
"Shutting down the server" on page
▶
"Disconnecting the power cord" on page
RX2540 M6
Hard disk drive (HDD) / solid state disk (SSD)
60.
65.
69.
52.
Upgrade and Maintenance Manual
69.
110. Select the
106.
Hardware: 10 minutes
Software: 10 minutes
53.
52.
217