Pre-registration
Grounding screw.
drive roll shaft.
Figure 7 Registration ground check points
Status Indicator RAPs
01A
Registration roll
shaft.
May 2013
2-12
Refer to
Figure
8. Check the registration ground contact spring and ground wire terminal. If
necessary remove and clean the spring, shafts and bearings, then re-assemble to improve
continuity.
NOTE: The two bearings in contact with the registration ground contact spring are manufac-
tured from conductive plastic. It is not possible to measure the resistance of these bearings
with the standard multi meter.
Figure 8 Registration ground contact spring
Registration ground
contact spring.