106
Creating Capture & Tape Action Workflows
Creating and Activating the Capture Action Workflow
Default Stop Behaviors for DAI Trigger
A recording is stopped by the Capture action when one of the following is seen
attached to a sample on the source with the corresponding Event ID:
- SCTE splice insert data with Splice_Insert_Type = 1.
- SCTE time signal data with a segmentation type ID of 0x11 indicating Program End.
Allow manual stop. When enabled, DAI jobs can be manually stopped via the
Lightspeed Live Capture web application.
Select Rules File. Browse to select the XML rules file used to enable automatic
recording to start and stop based on SCTE-104 markers.
Note: SCTE-104 rules files can be complex. It is best to contact a Telestream Sales
Engineer for details on configuring them correctly.
Issuing a Stop Command using the Web API
If a DAI SCTE-104 triggered recording should be stopped immediately and Allow
Manual Stop has not been enabled, you can issue the following Lightspeed Live Web
API Source command:
http://[IP of system hosting the SOURCE
Input]:[15000]/InsertScte35Message?source=[SOURCE
GUID]&scte35Message=ProgramEnd&eventID=0
The SOURCE GUID can be obtained by using the GetSource command. See the
Lightspeed Live Capture Web API Reference at the bottom of the Live Support page on
the Telestream website
for details on this command.