Generator - Subaru Legacy 2004 Service Manual

Hide thumbs Also See for Legacy 2004:
Table of Contents

Advertisement

STARTING/CHARGING SYSTEMS

3. Generator

A: REMOVAL
1) Disconnect the ground cable from battery.
2) Disconnect the connector and terminal from
generator.
• Non-turbo model
• Turbo model
3) Remove the V-belt covers.
4) Remove the front side belts.
<Ref. to ME(H4SO 2.0)-38, FRONT SIDE BELT,
REMOVAL, V-belt.> or <Ref. to ME(H4DOTC)-39,
FRONT SIDE BELT, REMOVAL, V-belt.>
Generator
5) Remove the bolts which install the generator
onto bracket.
B: INSTALLATION
IN-00203
Install in the reverse order of removal.
Tightening torque:
25 N
CAUTION:
Check and adjust the V-belt tension.
<Ref. to ME(H4SO 2.0)-39, INSPECTION, V-
belt.> or <Ref. to ME(H4DOTC)-40, INSPEC-
TION, V-belt.>
SC-00178
C: DISASSEMBLY
1) Remove the four through-bolts.
ME-00830
SC(H4SO 2.0)-14
!
m (2.5 kgf-m, 18.1 ft-lb)
SC-00179
SC-00179
SC-00078