Two-way Valve

EMISSION CONTROL (AUX. EMISSION CONTROL DEVICES)
7. Two-way Valve
A: REMOVAL
1) Lift-up the vehicle.
2) Disconnect the evaporation hoses from two-way
valve.
3) Remove the two-way valve as a unit with bracket
from body.
EC-00221
4) Remove the two-way valve from bracket.
B: INSTALLATION
Install in the reverse order of removal.
Tightening torque:
!
7.5 N
m (0.76 kgf-m, 5.5 ft-lb)
C: INSPECTION
Make sure the hoses are not cracked or loose.
EC(H4SO 2.0)-9