Diagnostic Procedure with Diagnostic Trouble Code (DTC)
ENGINE (DIAGNOSTICS)
Step
6
CHECK HARNESS BETWEEN ECM AND
TUMBLE GENERATOR VALVE POSITION
SENSOR CONNECTOR.
1) Turn the ignition switch to OFF.
2) Disconnect the connectors from tumble
generator valve position sensor.
3) Turn the ignition switch to ON.
4) Measure the voltage between tumble gen-
erator valve position sensor connector and
engine ground.
Connector & terminal
(E50) No. 1 (+) — Engine ground (
7
CHECK HARNESS BETWEEN ECM AND
TUMBLE GENERATOR VALVE POSITION
SENSOR CONNECTOR.
1) Turn the ignition switch to OFF.
2) Measure the resistance of harness
between ECM connector and tumble generator
valve position sensor connector.
Connector & terminal
(B136) No. 26 — (E50) No. 3:
8
CHECK HARNESS BETWEEN ECM AND
TUMBLE GENERATOR VALVE POSITION
SENSOR CONNECTOR.
Measure the resistance of harness between
tumble generator valve position sensor con-
nector and engine ground.
Connector & terminal
(E50) No. 3 — Engine ground:
9
CHECK POOR CONTACT.
Check poor contact in tumble generator valve
position sensor connector.
Check
Is the voltage more than 4.5 V? Go to step 7.
"
):
Is the resistance less than 1
!?
Is the resistance more than 1
M!?
Is there poor contact in tumble
generator valve position sen-
sor connector?
EN(H4SO 2.5)(diag)-194
Yes
Repair the har-
ness and connec-
tor.
NOTE:
In this case, repair
the following:
• Open circuit in
harness between
tumble generator
valve position sen-
sor and ECM con-
nector
• Poor contact in
tumble generator
valve position sen-
sor connector
• Poor contact in
ECM connector
• Poor contact in
coupling connector
• Poor contact in
joint connector
Go to step 8.
Repair the har-
ness and connec-
tor.
NOTE:
In this case, repair
the following:
• Open circuit in
harness between
tumble generator
valve position sen-
sor and ECM con-
nector
• Poor contact in
ECM connector
• Poor contact in
tumble generator
valve position sen-
sor connector
• Poor contact in
coupling connector
Go to step 9.
Repair the ground
short circuit in har-
ness between tum-
ble generator valve
position sensor
and ECM connec-
tor.
Repair the poor
Replace the tum-
contact in tumble
ble generator valve
generator valve
assembly. <Ref. to
position sensor
FU(H4SO 2.5)-28,
connector.
Tumble Generator
Valve Assembly.>
No