T1100 AS Hardware System Overview
Preliminary

Figure 3-5. T1100 AS Status Indicators

For more information about the diagnostics that manage these alarm and status
indicators, see "T1100 AS Diagnostics" on page A-6.

T1100 AS Chassis Installation and Replacement

The T1100 AS chassis is installed in the frame using slides that have inner and
outer rails. The outer slide rail is attached to the frame and the inner slide rail is
attached to the T1100 AS chassis (see Figure 5-1 on page 5-3). The chassis is
installed by sliding the inner rails into the outer rails.
DANGER: Moving a T1100 AS chassis requires two people. Each T1100 AS
chassis weighs approximately 30 kg (65 lbs) and may cause personnel injury or
damage to the internal components due to shock and vibration if not handled
properly.
The Tekelec 1100 AS chassis is also field replaceable. Tekelec 1100 AS replacement,
including disconnecting cables, mounting a replacement system (of identical
configuration), and reconnecting cables requires no more than 30 minutes.
NOTE: All I/O connections are at the rear of the Tekelec 1100 AS chassis.
Table 3-1 lists the dimensions of the Tekelec 1100 AS chassis.