20.
Depending on how the removable media disk drive assembly was accessed in
step 3, return the T1100 AS chassis to its original position using one of the
following procedures:
• Procedure 7-3, "Slide T1100 AS Chassis Back into Frame," on page 7-11
• Procedure 7-5, "Return a T1100 AS Chassis to the Frame," on page 7-16
21.
This procedure is complete.

How to Replace a Power Supply Module

The T1100 AS can be configured with either two AC power supply modules or
two DC power supply modules. Do not mix AC and DC power supply modules.
Power supply modules are hot-swappable. Do not remove both power supply
modules at the same time.
WARNING: Do not mix AC and DC power supply modules in the same
chassis.
SHOW ME: To view a video (with sound) that shows some steps of the
following procedure,
and data, be sure to read all the steps in the following procedure. For more
information about how to view this video, see "Programs Needed to View
Linked Documents" on page 1-4.
Procedure 7-11. Replace a power supply module
1.
Engage a plane blade screwdriver into the notch on the edge of the locking
ring. The ring is on the right side of the power supply module.
2.
Rotate the ring down to disengage the power supply module. As the ring is
rotated, the power supply module is cammed out of its connector.
7-38
Preliminary
click
here. For personnel safety and to protect equipment
Field Replaceable Units
910-2969-001 Revision H, February 2007