How To Replace T1100 As Frus; How To Replace The Air Filters - Tekelec 1100 Hardware Manual

Application server
Hide thumbs Also See for 1100:
Table of Contents

Advertisement

Field Replaceable Units
13.
Replace any plastic panels and doors that were removed.
14.
This procedure is complete.
Next, turn the power back on as described in "How to Power Up" on page 6-15.

How to Replace T1100 AS FRUs

Use one of the following procedures in this section to replace a T1100 AS FRU:
• Procedure 7-6, "Replace Rectangular and Square Air Filters," on page 7-20
• Procedure 7-8, "Replace a Square Fan Assembly," on page 7-23
• Procedure 7-9, "Replace a Hard Disk Drive Assembly," on page 7-26
• Procedure 7-10, "Replace a Removable Media Disk Drive Assembly," on page
7-32
• Procedure 7-12, "Replace a PCI Card," on page 7-40
• Procedure 7-13, "Replace a T1100 AS Chassis FRU," on page 7-46

How to Replace the Air Filters

There are two air filters on the T1100 AS: the rectangular air filter and the square
air filter. It is recommended that the air filters on the T1100 AS chassis be replaced
at least once a month. Before beginning these procedures, ensure that spare filters
are on hand. If the number of spare filters is running low, order additional filters.
NOTE: It is not necessary to slide out or remove the T1100 AS chassis from its
frame in order to replace the filter.
SHOW ME: To view a video (with sound) that shows some steps of the
following procedure,
and data, be sure to read all the steps in the following procedure. For more
information about how to view this video, see "Programs Needed to View
Linked Documents" on page 1-4.
910-2969-001 Revision H, February 2007
DRAFT
click
here. For personnel safety and to protect equipment
7-19

Advertisement

Table of Contents
loading