Figure 7-1. T1100 As Chassis Front View - Tekelec 1100 Hardware Manual

Application server
Hide thumbs Also See for 1100:
Table of Contents

Advertisement

SHOW ME: To view a video (with sound) that shows some steps of the
following procedure,
and data, be sure to read all the steps in the following procedure. For more
information about how to view this video, see "Programs Needed to View
Linked Documents" on page 1-4.
Procedure 7-2.
WARNING:
frame when working on electronic components.
1.
From the front of the frame, remove the # 12-24 Phillips screw from each
chassis retention bracket (see Figure 7-1). Do not remove the screws in the
frame adapter brackets.

Figure 7-1. T1100 AS Chassis Front View

2.
From the front of the frame, using the handles (T1000) or the knurled screws
on the side of the chassis (T1100), pull forward until the release buttons on the
inner arms of the slide assemblies pop into the holes on each side. While
gently sliding the chassis, observe the cables to avoid binding, stretching, or
disconnecting.
7-10
Preliminary
click
here. For personnel safety and to protect equipment
Slide T1100 AS Chassis Out from Frame
Always wear an ESD wrist strap grounded to the bench or
Field Replaceable Units
910-2969-001 Revision H, February 2007

Advertisement

Table of Contents
loading

Table of Contents