8.
While supporting the failed unit, use the #2 phillips screwdriver to remove
the screws holding the mounting bracket of the unit to the frame.
9.
Pull failed unit out of the frame. Remove the mounting brackets from the old
unit.
10.
Secure the mounting brackets to the replacement unit.
11.
While holding the replacement unit in place, start the available screws
0.5 inch (P/N 601-0010-01) into the hole of the mounting bracket on either
side of the unit. Still supporting the unit, install two screws into the hole
though the bracket into the frame and tighten.
12.
First attach the power cables. Then attach the logic ground. Be sure to attach
cables to the same locations they were attached to at the start of the procedure.
13.
Attach the ethernet cables to the same locations they were attached to at the
start of this procedure.
14.
If the unit has a power switch, switch it ON. Turn on the circuit breakers to
supply power to the unit.
15.
Using a VOM meter, check that there is adequate power (-48V) going to the
unit. Verify that the power LED on the unit is lit.
16.
If this procedure has been performed to replace console server or an Ethernet
switch, contact the Customer Care Center (see "Customer Assistance" on
page 1-7) to determine whether additional steps need to be performed.
17.
This procedure is complete.