Figure 7-4. T1100 AS Chassis Rear View

7.
Route and connect the power and data cables through the cable management
system to the T1100 AS chassis. Check the labels on the cables and attach them
to the appropriate connectors on the rear of the T1100 AS chassis. Consult the
cable running list, labels on the cables, and PCI configuration labels on the
right of the chassis as seen from the rear. See Figure 7-4.
8.
Loosen the screws that attach the chassis retention brackets to the T1100 AS
chassis. The chassis retention brackets are adjusted in step 11. See Figure 7-3
on page 7-17 for screw locations.
9.
From the front of the frame, simultaneously press the round release buttons
and slowly push the chassis into the frame while observing the cables to avoid
binding or stretching.
NOTE: When the chassis stops moving, the front of the T1100 AS should
be slightly recessed to allow clearance behind the frame door when closed.
10.
Adjust the chassis retention brackets on the front of the T1100 AS chassis to
contact the frame adapter brackets when the chassis is positioned correctly in
the frame.
11.
Tighten the screws that attach the chassis retention brackets to the T1100 AS
chassis.
12.
Secure the chassis with one # 12-24 screw in the chassis retention brackets on
each side.
7-18
Preliminary
910-2969-001 Revision H, February 2007