How To Access T1100 As Frus; How To Slide T1100 As Chassis Out From Frame - Tekelec 1100 Hardware Manual

Application server
Hide thumbs Also See for 1100:
Table of Contents

Advertisement

Field Replaceable Units

How to Access T1100 AS FRUs

A T1100 AS FRU can be accessed in one of the following ways:
WARNING:
when working on electronic components.
• Without moving the chassis from its position in the frame. The air filters and
power supply modules can be accessed this way; see "How to Replace the Air
Filters" on page 7-19 and "How to Replace a Power Supply Module" on
page 7-38.
• By sliding the chassis partway out of the frame (see "How to Slide T1100 AS
Chassis Out from Frame" on page 7-9). This method can be used to access one
or more of the following:
— Fan assembly
— Hard drive assembly
— Removable media drives assembly
— PCI cards
• By removing the chassis from the frame and placing it on a workbench (see
"How to Remove T1100 AS Chassis from a Frame" on page 7-12)
— This method must be used to access the T1100 AS chassis for replacement
— This method may be used to access one or more of the following:
–Fan assembly
–Hard drive assembly
–Removable media drives assembly
–PCI cards

How to Slide T1100 AS Chassis Out from Frame

The following FRUs can be replaced without removing the T1100 AS chassis
entirely out of the frame:
• Fan assemblies
• Fan filters
• Hard disk drive assemblies
• Removable media disk drives assembly
• PCI cards
• Power Supply Modules
910-2969-001 Revision H, February 2007
DRAFT
Always wear an ESD wrist strap grounded to the bench or frame
7-9