Field Replaceable Units
CAUTION: Use only listed closed loop connectors for connection to the supply.
CAUTION: When some CPCI cards arrive from the manufacturer, they may have a
small plastic cover over the screws and/or the alignment ejector pins. Remove and
discard these plastic covers. If inserting the cards takes an excessive amount of force,
check for obstructions. Forcing the card into a slot may damage the ejector handle or
pin.

T1100 AS Hardware System FRUs and Part Numbers

The following T1100 AS hardware system components can be replaced in the field:
Air filters (rectangular filter P/N 551-0022-03 and square filter P/N 551-0022-02)
Fan assemblies (rectangular fan P/N 840-1125-03 and square fan P/N 840-1133-01).
SATA hard drives (P/N 870-2787-02)
Removable media drives assembly (P/N 870-2785-02)
Power supply module (AC P/N 870-2795-04 and DC P/N 870-2795-03)
Peripheral Component Interface (PCI) cards
PCI Ethernet dual port 10/100/1000 (P/N 870-2706-04)
Modem (P/N 870-2707-02)
Quad serial (P/N 870-2708-02)
PCI express interface/quad Gb ethernet (P/N 870-2790-02, slot 9)
Out of band management card (P/N 870-2798-02, slot 8)
Assy serial ATA interface card (P/N 870-2799-01, slot 2)
T1100 AS chassis (DC P/N 870-2754-01 AC P/N 870-2754-02). Note: hard drive assemblies and
PCI cards from the failed chassis can be moved to the replacement chassis.
Ethernet switch or hub (see
page 104)

T1100 AS FRUs

Table 9: T1100 AS Field Replaceable Units and Part Numbers
components that have been designed to be replaceable in the field. Most of these components are
located for easy access; they can be replaced without completely removing them from the frame.
In addition, some of them can even be replaced without needing to shut off power to theT1100
AS chassis.
WARNING: When you need to replace a FRU for which the power must be shut
off, always first attempt to perform a soft shutdown of the application systems (refer
to the application manual).
102
How to Replace a Console Server, Router, Ethernet Switch, or Hub
Hardware Manual
on page 103 shows theT1100 AS
910-2969-001 Revision K, June 2009
on