(c) RECV instruction execution timing
When data are stored in a channel of the own station, the corresponding RECV execution request flag
(SB0030 and SB0031) turns on.
Use the flag as a start contact and execute the RECV instruction.
Upon completion of the RECV instruction, the flag turns off.
Number
SB0030
SB0031
• When completed
For details on the RECV instruction execution time, refer to the following.
Page 289, Section 10.8 (2) (d)
• When failed
Master/local module
Own station CPU
(3) Checking error details
If the dedicated instruction fails, error details can be checked by either of the following methods:
(a) In GX Works2
Error details can be checked using the CC-Link IE Field Network diagnostics. (
(b) Using devices
Completion status indication device ((D2)+1) turns on, and an error code is stored in Completion status
((S1)+1) of the control data.
According to the error code, check the error details and take a corrective action. (
12.5)
298
RECV execution request flag (1)
RECV execution request flag (2)
Sequence scan
0
RECV execution
request flag (2) (SB0031)
Completion device
(Device specified in (D2))
Completion status
indication device
(Device of (D2)+1)
Completion status
(Device of (S1)+1)
Name
Channel 2
RECV
END
0
END
0
Arrival timeout
END
0
END
1 scan
Error code
Page 206, CHAPTER 9)
Page 439, Section
0
END