Mitsubishi Electric QJ71GF11-T2 User Manual page 504

Melsec-q series cc-link ie field network master/ local module
Table of Contents

Advertisement

Number
Name
PORT1 receive error
SW0075
detection count
PORT1 total no. of
SW0076
received data (lower 1
word)
PORT1 total no. of
SW0077
received data (upper 1
word)
SW007A
Event count
PORT2 cable
SW007C
disconnection
detection count
PORT2 receive error
SW007D
detection count
PORT2 total no. of
SW007E
received data (lower 1
word)
PORT2 total no. of
SW007F
received data (upper 1
word)
SW0080
Execution status
to
(REMFR/REMTO)
SW009F
502
Description
Stores the (cumulative) count that error data was received at the PORT1.
The count stores only error data that is not transmitted to all stations.
When Clear communication error count (SB0006) is turned on, the
stored occurrence rate is cleared.
When FFFF
is counted, counting stops.
H
Stores the (cumulative) count that data was received at the PORT1.
When Clear communication error count (SB0006) is turned on, the
stored occurrence rate is cleared.
When FFFFFFFF
is counted, counting stops.
H
Stores the count of the network event history.
This stored count is cleared when Event count clear (SB0009) is turned
on.
When FFFF
is counted, counting stops.
H
Stores the (cumulative) count that was detected for cable disconnections
at the PORT2.
When Clear communication error count (SB0006) is turned on, the
stored occurrence rate is cleared.
When FFFF
is counted, the value returns to 0 and the module
H
continues to count.
Stores the (cumulative) count that error data was received at the PORT2.
The count stores only error data that is not transmitted to all stations.
When Clear communication error count (SB0006) is turned on, the
stored occurrence rate is cleared.
When FFFF
is counted, counting stops.
H
Stores the (cumulative) count that data was received at the PORT2.
When Clear communication error count (SB0006) is turned on, the
stored occurrence rate is cleared.
When FFFFFFFF
is counted, counting stops.
H
Stores the REMFR/REMTO execution status for each channel.
SW0080
Channel 1
SW008B
SW0081
Channel 2
SW008C
SW0082
Channel 3
SW008D
SW0083
Channel 4
SW008E
SW0084
Channel 5
SW008F
SW0085
Channel 6
SW0090
SW0086
Channel 7
SW0091
SW0087
Channel 8
SW0092
SW0088
Channel 9
SW0093
SW0089
Channel 10
SW0094
SW008A
Channel 11
SW0095
0: Normal completion
1 or higher: Abnormal completion (
Channel 12
SW0096
Channel 23
Channel 13
SW0097
Channel 24
Channel 14
SW0098
Channel 25
Channel 15
SW0099
Channel 26
Channel 16
SW009A
Channel 27
Channel 17
SW009B
Channel 28
Channel 18
SW009C
Channel 29
Channel 19
SW009D
Channel 30
Channel 20
SW009E
Channel 31
Channel 21
SW009F
Channel 32
Channel 22
Page 439, Section 12.5)