(c) Response data (the system sets all)
When the target station No. ((S1)+5) is all stations or group specification (81
not stored.
Device
Item
0081
(D1)+0
Request type
0091
0002
Sub-request
(D1)+1
type
0001
Read clock data is stored in the BCD format.
(D1)+2
(D1)+3
Read clock data
(D1)+4
(D1)+5
For details on the clock function, refer to the user's manual for the CPU module used.
Setting data
: Clock data read
H
: Clock data write (when station number is specified by (S1)+5)
H
: Clock data read
H
: Clock data write
H
b15
(D1)+2
Month (01
to 12
)
H
H
(D1)+3
Hour (00
to 23
)
H
H
(D1)+4
Second (00
to 59
H
H
(D1)+5
00
H
CHAPTER 10 DEDICATED INSTRUCTIONS
H
b8 b7
b0
Year (00
to 99
), last 2 digits
H
H
Day (01
to 31
)
H
H
)
Minute (00
to 59
)
H
H
Day of week (00
to 06
)
H
H
00
(Sun.) to 06
(Sat.)
H
H
to A0
, FF
), response data are
H
H
Clock data
Clock data
read
write
: Stores  : Does not store