Mitsubishi Electric QJ71GF11-T2 User Manual page 482

Melsec-q series cc-link ie field network master/ local module
Table of Contents

Advertisement

Number
Name
PORT2 linkup status
SB006B
(own station)
PORT1 error frame
SB006C
reception status (own
station) (1)
PORT2 error frame
SB006D
reception status (own
station) (1)
PORT1 error frame
reception detection
SB006E
status (own station)
(latch) (1)
PORT2 error frame
reception detection
SB006F
status (own station)
(latch) (1)
Master station
SB0070
information
Submaster station
SB0071
information
Scan mode setting
SB0072
information
Reserved station
SB0074
specification status
Error invalid station
SB0075
setting status
Submaster station
SB0076
setting information
480
Description
Stores the linkup status of PORT2 (own station).
OFF: Linkup in progress
ON: Linkdown in progress
The time that the linkup starts after power-on or Ethernet cable
connection may vary. Normally, it takes a few seconds.
Depending on device status on the line, a linkup process is repeated,
resulting in the increase in the time.
Stores if a receive frame error line status caution level has occurred in
the own station's PORT1.
OFF: A receive frame error line status caution level has not yet been
occurred.
ON: A receive frame error line status caution level has been occurred.
Stores if a receive frame error line status caution level has occurred in
the own station's PORT2.
OFF: A receive frame error line status caution level has not yet been
occurred.
ON: A receive frame error line status caution level has been occurred.
Stores if a receive frame error line status caution level has occurred in
the own station's PORT1 from power-on until the present.
OFF: A receive frame error line status caution level has not yet been
occurred.
ON: A receive frame error line status caution level has been occurred.
Stores if a receive frame error line status caution level has occurred in
the own station's PORT2 from power-on until the present.
OFF: A receive frame error line status caution level has not yet been
occurred.
ON: A receive frame error line status caution level has been occurred.
Stores data link status when the submaster function is used.
OFF: Data link by the master station
ON: Data link by the submaster station
Stores if a submaster station exists.
OFF: No submaster station
ON: Submaster station exists
Stores the scan mode setting status.
OFF: Asynchronous mode
ON: Synchronous mode
Stores the reserved station specification status due to parameters.
The reserved station number can be checked using Reserved station
setting status (SW00C0 to SW00C7).
OFF: Not specified
ON: Specified
Stores the Error invalid station setting status due to parameters.
The error invalid station number can be checked using Error invalid
station setting status (SW00D0 to SW00D7).
OFF: Not specified
ON: Specified
Stores the status of the submaster station setting.
OFF: No setting
ON: Set
Availability
Master
station
Local
(submaster
station
station)
×