Mitsubishi Electric QJ71GF11-T2 User Manual page 88

Melsec-q series cc-link ie field network master/ local module
Table of Contents

Advertisement

Item
• For the master station and submaster station
Online (Normal Mode)
Online (High Speed
Mode)
Offline
Mode
H/W Test
Self-Loopback Test
Loop Test
• For local stations
Online
Offline
H/W Test
Self-Loopback Test
Set parameters of slave stations (the number of points and
assignment of link devices) in the master station and submaster
station.
When the checkbox next to "Set the network configuration setting in
the CC IE Field configuration window" is checked, the button will be
changed to
In this manual, the operation with the checkbox checked is described
for explanation purpose.
86
Description
Set a master station mode or a submaster station mode. Two online
modes are available. Select an online mode according to the
system.
Mode
This mode performs cyclic transmission and
transient transmission without losing their inherent
speed performance. This mode is suitable for a
system that performs I/O control and analog
control, and transmits large amount of data for
management, monitoring, and diagnostics by
transient transmission. (
Appendix 6)
Use this mode for general applications.
This mode preferentially performs cyclic
transmission for high-speed communications. This
mode is suitable for a system to achieve I/O
control, analog control, and digital I/O at high-
speed. (
Note that the maximum number of points assigned
to RWw/RWr is 256 points per local station.
In this mode, the processing speed of transient
transmission is slower than in "Online (Normal
Mode)".
Select this mode to disconnect the master/local
module from the network for stopping data link
with other stations.
Select this mode to perform a hardware test.
(
Page 64, Section 6.2.1)
Select this mode to perform a self-loopback test.
(
Page 66, Section 6.2.2)
Select this mode to perform a loop test.
*1
(
Page 71, Section 6.4.1)
*1
This mode cannot be selected for the submaster
station.
Select a local station mode.
Mode
Select this mode to connect the master/local
module to the network for performing data link with
other stations.
Select this mode to disconnect the master/local
module from the network for stopping data link
with other stations.
Select this mode to perform a hardware test.
(
Page 64, Section 6.2.1)
Select this mode to perform a self-loopback test.
(
Page 66, Section 6.2.2)
Description
Page 529,
Page 529, Appendix 6)
Description
.
Setting range
• Online (Normal Mode)
• Online (High Speed Mode)
• Offline
• H/W Test
• Self-Loopback Test
• Loop Test
(Default: Online (Normal Mode))
• Online
• Offline
• H/W Test
• Self-Loopback Test
(Default: Online)
Page 88, Section 7.3