Mitsubishi Electric QJ71GF11-T2 User Manual page 511

Melsec-q series cc-link ie field network master/ local module
Table of Contents

Advertisement

Number
Name
SW0108
Station number
to
duplication occurrence
SW010F
status
SW0110
Operation status (each
to
station) (2)
SW0117
Description
Stores the occurrence status of station number duplication.
0: No duplication of station number
1: Station number duplicated
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
SW0108
16 15 14 13 12 11 10
SW0109
32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17
SW010A
48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33
SW010B
64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49
SW010C
80 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65
SW010D
96 95 94 93 92 91 90 89 88 87 86 85 84 83 82 81
SW010E
112 111 110 109 108 107 106 105
SW010F
— — — — — — — —
Each number in the table represents a station No.
is fixed to 0.
Stores the minor error or continuation error status of each station.
When the target station is the master/local module, the status of the
control CPU is stored.
0: Normal or moderate/major error (stop error) occurring
1: Minor error (continuation error) occurring
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
SW0110
16 15 14 13 12 11 10
SW0111
32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17
SW0112
48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33
SW0113
64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49
SW0114
80 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65
SW0115
96 95 94 93 92 91 90 89 88 87 86 85 84 83 82 81
SW0116
112 111 110 109 108 107 106 105 104 103 102 101 100 99 98 97
SW0117
Each number in the table represents a station No.
is fixed to 0.
(Conditions)
• This is enabled when Baton pass status (own station) (SB0047) is off.
• Holds the data immediately before the error.
• This is enabled only for normal stations in Baton pass status (each
station) (SW00A0 to SW00A7).
• Reserved stations and stations higher than the maximum station No.
are ignored.
9
8
7
6
5
4
3
2
1
104 103 102 101 100 99 98 97
120 119 118 117 116 115 114 113
9
8
7
6
5
4
3
2
1
120 119 118 117 116 115 114 113
APPENDICES
Availability
Master
station
Local
(submaster
station
station)
509