Request Data (A User Sets All) - Mitsubishi Electric QJ71GF11-T2 User Manual

Melsec-q series cc-link ie field network master/ local module
Table of Contents

Advertisement

Device
Item
Response data
(S1)+10
length
(S1)+11
Clock set flag
(S1)+12 to
Clock data of
(S1)+15
abnormal end
Error-detected
station's network
(S1)+16
*1
No.
Error-detected
(S1)+17
station number
*1
If Completion status ((S1)+1) is "Channel in use (dedicated instruction) (error codes: D25A
stored.
(b) Request data (a user sets all)
Device
Item
(S2)+0
Request type
(S2)+1
Sub-request type
310
Stores the response data count (word).
(Word count of data to be stored in own station start device (D1)
where response data is stored)
2: Remote RUN/STOP
The valid or invalid status of data after (S1)+12 is stored.
(Data is stored when "1: Data at the time of abnormal end is set in
the area starting from (S1)+11." is set in the abnormal end type in
(S1)+0.) The stored data is not cleared even if the dedicated
instruction is normally completed.
0: Invalid
1: Valid
Clock data of abnormal end are stored in BCD format.
(Data is stored when "1: Data at the time of abnormal end is set in
the area starting from (S1)+11." is set in the abnormal end type in
(S1)+0.) The stored data is not cleared even if the dedicated
instruction is normally completed.
b15
Month (01
(S1)+12
Hour (00
(S1)+13
Second (00
(S1)+14
(S1)+15
Year (00
to 99
H
When the target station is QnACPU, "00
first two digits of the year).
The network No. of the station in which an error was detected is
stored.
(Data is stored when "1: Data at the time of abnormal end is set in
the area starting from (S1)+11." is set in the abnormal end type in
(S1)+0.) The stored data is not cleared even if the dedicated
instruction is normally completed.
1 to 239: Network No.
The station number of the station in which an error was detected is
stored.
(Data is stored when "1: Data at the time of abnormal end is set in
the area starting from (S1)+11." is set in the abnormal end type in
*1
(S1)+0.) The stored data is not cleared even if the dedicated
instruction is normally completed.
Master station: 125 (7D
Local station, intelligent device station, submaster station: 1 to 120
0010
: When station No. is specified by (S1)+5
H
0030
: When all stations or groups are specified by (S1)+5
H
0001
: Remote RUN
H
0002
: Remote STOP
H
Setting data
b8 b7
to 12
)
Year (00
to 99
), last 2 digits
H
H
H
H
to 23
)
Day (01
to 31
H
H
H
to 59
)
Minute (00
to 59
H
H
H
Day of week (00
), first 2 digits
H
H
00
(Sun.) to 06
H
" is stored in the year (the
H
)
H
Setting data
Setting range
b0
)
H
)
H
to 06
)
H
(Sat.)
H
and D25B
H
Remote RUN
Set by
System
System
System
System
System
)", data is not
H
Remote STOP

Advertisement

Table of Contents
loading

Table of Contents