Completion of Instruction Execution ("Instruction execution complete" Flag,
"Instruction execution abnormal end" Flag)
Use the "Instruction execution complete" flag or "Instruction execution abnormal end" flag to check whether
execution of the positioning instruction has been completed properly.
The "Instruction execution complete" flag and "Instruction execution abnormal end" flag are turned on or off
after each instruction. Use these flags just after the execution of each instruction.
• "Instruction execution complete" flag (M8029): Will be turned on if the instruction is executed properly.
• "Instruction execution abnormal end" flag (M8329): Will be turned on if the instruction is not executed
properly.
*1.
Caution:
If the "Instruction execution complete" flag or "Instruction execution abnormal end" flag is turned on, then the
execution of the instruction (pulse outputting operation, etc.) is complete. However, it is not certain whether
the servo motor has stopped or not. Check the "positioning completion" signal of the servo amplifier (drive
unit) to determine whether the servo motor has stopped.
4.4.3

"Pulse Output Monitor" (BUSY/READY) Flag

Use the "pulse output monitor" (BUSY/READY) flag to check whether pulses are being output to the pulse
output destination device. The following table shows the "pulse output monitor" (BUSY/READY) flag of each
pulse output destination device.
Pulse output
destination device
*1.
*2.
4.4.4

"Positioning Instruction Activation" Flag

Use the "positioning instruction activation" flag of each pulse output destination device to check whether or
not a positioning instruction is being executed for the pulse output destination device. Use this flag to prevent
simultaneous activation of two or more positioning instructions for the same pulse output destination device.
Pulse output
destination device
*1.
*2.
B - 66
Downloaded from
ManualsNet.com
/FX
/FX
PLC User's Manual - Positioning Control Edition
3U
3UC
Will not be turned on for execution of the PLSV instruction.
"Pulse output monitor"
(BUSY/READY) flag
Y000
Y001
*1
Y002
*2
Y003
Y002 is not available in FX
Y003 is available only when two high-speed output special adapters are connected to the FX
"Positioning instruction
Activation" flag
Y000
Y001
*1
Y002
*2
Y003
Y002 is not available in FX
Y003 is available only when two high-speed output special adapters are connected to the FX
search engine
For programming details, refer to Subsection 4.7.4.
M8340
M8350
M8360
M8370
PLC (14-point and 24-point type) and FX
3G
M8348
ON: The positioning instruction is being activated for the
corresponding pulse output destination.
M8358
(Even after instruction execution is completed, if the
M8368
instruction is still being activated, the flag will not be
turned off.)
OFF: The positioning instruction is not being activated for the
M8378
corresponding pulse output destination.
PLC (14-point and 24-point type) and FX
3G
4 Before Programming
4.4 Current Value and Flag for Monitoring of Operation
Status of flag and pulse
Outputting pulse (BUSY): Flag = ON
Pulse outputting stopped (READY): Flag = OFF
/FX
PLC.
3S
3GC
Status of flag and pulse
/FX
PLC.
3S
3GC
*1
PLC.
3U
PLC.
3U