Group Drive; Speed Sensor Connection - BONFIGLIOLI ACTIVE Cube ACU 201-01 Operating Instructions Manual

Frequency inverter 230 v / 400 v 0.25 kw ... 132 kw
Table of Contents

Advertisement

6.4.3.4 Group drive

In the case of a group drive (several motors at one frequency inverter), the total
length shall be divided across the individual motors according to the value given in the
table. Please note that group drive with synchronous servomotors is not possible.
Use a thermal monitoring element on each motor (e.g. PTC resistor) in order to avoid
damage.

6.4.3.5 Speed sensor connection

Install sensor cables physically separate from motor cables. Comply with the sensor
manufacturer's specifications.
Connect the shield close to the frequency inverter and limit the length to the neces-
sary minimum.
58
Operating Instructions ACU
06/13

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ACTIVE Cube ACU 201-01 and is the answer not in the manual?

Questions and answers

Владимир
February 17, 2025

Конфигурация 610 контроллером крутящего момента. Опорный крутящий момент представлен в видепроцент и он передается в соответствующие эксплуатационные показателиприложение. Переключение между регулированием переменной скорости и регулированием крутящего моментаУправление осуществляется без рывков во время работ? Как подробнее узнать об этом режиме? Нужно обеспечить останов с заданным моментом на валу мотора