Operation mode filling level 1, parameter
440 = 2
Operation mode
This operation mode can be used, for example, for contents level control.
If the actual value is missing, the function brings the output frequency to an adjusta-
ble value.
The minimum value monitoring prevents an acceleration of the drive if the actual
value is missing.
If the actual value is missing (< 0.5%) the output frequency is guided to the
Fixed
441. This is done using the set
421.
frequency
Deceleration (clockwise)
The
441 must be in the range between
418
Fixed frequency
Minimum frequency
and
419. If the
441 is set to a value smaller
Maximum frequency
Fixed frequency
than the
418, the output frequency is guided to
Minimum frequency
Minimum fre-
418. The frequency will not drop below
418.
quency
Minimum frequency
If the actual value is available again, the controller continues operation automatically.
The Integral value is reset when the Actual value returns.