No.
477 Gradient percentage ramp
478 Actual percentage source
479 time constant positioning contr.
480 Fixed frequency 1
481 Fixed frequency 2
482 Fixed frequency 3
483 Fixed frequency 4
489 JOG frequency
490 Operation mode
491 Division Marks
496 Operation mode
497 Divider
506 Trigger threshold
507 Trigger threshold
510 Setting Frequency
511 EC1 Gear Factor Numerator
512 EC1 Gear Factor Denominator
515 Integral Time Speedtracking
517 Setting Frequency Off Delta
518 Minimum Reference Percentage
519 Maximum Reference Percentage
520 Fixed percentage 1
521 Fixed percentage 2
522 Fixed percentage 3
523 Fixed percentage 4
530 Operation mode digital output 1
532 Operation mode digital output 3
535 Op. Mode ext. Error
536 Create Warning Mask
540 Operation mode comparator 1
541 Comparator On above
Operating Instructions ACU
06/13
Percentage ramp
Description
Technology Controller
Positioning
Fixed Frequencies
Speed Sensor 1
PWM-/repetition frequency input
Brake Chopper
Motor Chopper
Digital Outputs
Speed Sensor 1
Speed controller
Digital Outputs
Percentage Value Limits
Fixed Percentages
Digital Outputs
Unit
Setting range
%/s
0 ... 60000
-
Selection
ms
1.00 ... 9999.99
Hz
-999.99 ... 999.99
Hz
-999.99 ... 999.99
Hz
-999.99 ... 999.99
Hz
-999.99 ... 999.99
Hz
-999.99 ... 999.99
-
Selection
-
1 ... 8192
-
Selection
-
1 ... 8192
(201)
225 ... 1000.0
V
(401)
425 ... 1000.0
(201)
225 ... 1000.0
V
(401)
425 ... 1000.0
Hz
0.00 ... 999.99
-
-300.00 ... 300.00
-
0.01 ... 300.00
ms
1 ... 60 000
Hz
0.00 ... 999.99
%
0.00 ... 300.00
%
0.00 ... 300.00
%
-300.00 ... 300.00
%
-300.00 ... 300.00
%
-300.00 ... 300.00
%
-300.00 ... 300.00
-
Selection
-
Selection
-
Selection
-
Selection
-
Selection
%
-300.00 ... 300.00
Chapter
14.8
17.3
12.6.2
14.6.1
14.6.1
14.6.1
14.6.1
14.6.2
10.4.1
10.4.2
14.11
14.11
18.4
18.7.1
15.3.2
10.4.3
10.4.3
17.5.4.3
15.3.2
14.3
14.3
14.6.3
14.6.3
14.6.3
14.6.3
15.3
15.3
15.4.12
15.3.8
15.5.2
15.5.2
281

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ACTIVE Cube ACU 201-01 and is the answer not in the manual?

Questions and answers

Владимир
February 17, 2025

Конфигурация 610 контроллером крутящего момента. Опорный крутящий момент представлен в видепроцент и он передается в соответствующие эксплуатационные показателиприложение. Переключение между регулированием переменной скорости и регулированием крутящего моментаУправление осуществляется без рывков во время работ? Как подробнее узнать об этом режиме? Нужно обеспечить останов с заданным моментом на валу мотора

Subscribe to Our Youtube Channel

Table of Contents

Save PDF