Parameter Menu (Para) - BONFIGLIOLI ACTIVE Cube ACU 201-01 Operating Instructions Manual

Frequency inverter 230 v / 400 v 0.25 kw ... 132 kw
Table of Contents

Advertisement

No.
367 Application Warning Status
470 Rotations
537 Actual warning mask
627 Actual Appl. Warning Mask
797 SET-UP Status
22.2

Parameter Menu (PARA)

No.
0 Serial Number
1 Optional Modules
12 Inverter Software Version
15 Copyright
27 Set password
28 Control level
29 User Name
30 Configuration
33 Language
34 Program(ming)
37 Start Positioning of Axle
39 Switch-on temperature
48 Reference frequency
49 Handshake Traverse Function
58 Technology Controller Release
62 Frequency Motorpoti Up
63 Frequency Motorpoti Down
66 Fixed frequency change-over 1
67 Fixed frequency change-over 2
68 Start clockwise
69 Start anticlockwise
70 Data set change-over 1
71 Data set change-over 2
72 Percent Motorpoti Up
73 Percent Motorpoti Down
75 Fixed perc. value change-over 1
76 Fixed perc. value change-over 2
83 Timer 1
84 Timer 2
87 Start 3-wire control
103 Error Acknowledgment
164 n-/M Control Change-Over
183 External error
204 Therm. Contact
278
Error Environment
Description
Positioning
Digital Outputs
Self-configuration
Inverter Data
Description
Fan
Shot effect function
Digital inputs
Digital inputs
Operating Instructions ACU
Unit
Display range
-
A0000 ... AFFFF
6
U
0.000 ... 1⋅10
-
AXXXXXXXX
-
AXXXX
-
OK / NOK
Unit
Setting range
-
Characters
-
Characters
-
Characters
-
Characters
-
0 ... 999
-
1 ... 3
-
32 characters
-
Selection
-
Selection
-
0 ... 9999
-
Selection
deg.C
0 ... 60
-
Selection
-
Selection
-
Selection
-
Selection
-
Selection
-
Selection
-
Selection
-
Selection
-
Selection
-
Selection
-
Selection
-
Selection
-
Selection
-
Selection
-
Selection
-
Selection
-
Selection
-
Selection
-
Selection
-
Selection
Selection
-
Selection
Chapter
21.4
12.6
15.3.8
15.3.9
8.5
Chapter
9.1
9.2
9.3
9.3
9.4
9.5
9.6
9.7
9.8
9.9
12.6.2
18.2
18.8
15.4.10
17.3
15.4.9
15.4.9
15.4.8
15.4.8
15.4.1
15.4.1
15.4.7
15.4.7
15.4.9
15.4.9
15.4.8
15.4.8
15.4.4
15.4.4
15.4.2
15.4.3
15.4.6
15.4.12
15.4.5
06/13

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ACTIVE Cube ACU 201-01 and is the answer not in the manual?

Questions and answers

Владимир
February 17, 2025

Конфигурация 610 контроллером крутящего момента. Опорный крутящий момент представлен в видепроцент и он передается в соответствующие эксплуатационные показателиприложение. Переключение между регулированием переменной скорости и регулированием крутящего моментаУправление осуществляется без рывков во время работ? Как подробнее узнать об этом режиме? Нужно обеспечить останов с заданным моментом на валу мотора

Table of Contents

Save PDF