9 Inverter Data
The series ACU frequency inverters are suited for a wide range of applications. The
modular hardware and software structure enables customer-specific adaptation. The
available hardware functionality of the frequency inverter is displayed in the control
unit and the optional control software VPlus. The software parameters can be adjust-
ed to meet the requirements of the specific application.
9.1
Serial Number
The
Serial Number
quency inverter. Information on the device type and the fabrication data (8-digit
number) are indicated. Additionally, the serial number is printed on the nameplate.
Serial number
Nameplate:
9.2
Optional Modules
Modular extension of the hardware is possible via the plug-in slots. The
modules
are displayed on the control unit and in the optional control software VPlus after ini-
tialization. For the parameters required for the expansion module, refer to the corre-
sponding operating instructions.
9.3
Inverter Software Version
The firmware stored in the frequency inverter defines the available parameters and
functions of the software. The software version is indicated in parameter
software version
the rating plate of the frequency inverter.
Inverter software version
Nameplate:
Copyright
9.4
Set Password
As a protection against unauthorized access, the parameter
set such that anyone who wants to change parameters must enter this password this
password before. A change of parameter is only possible if the password in entered
correctly. If the
for access to the parameters. The previous password is deleted.
No.
27 Set password
118
0 is entered on the nameplate during the fabrication of the fre-
0 :
1 detected by the frequency inverter and the corresponding designations
CM-232 ; EM-IO-01
12. In addition to the version, the 6-digit software key is printed on
12:
15
27 parameter is set to zero, no password is required
Set password
Parameter
Description
Operating Instructions ACU
603409000 ; 06053980 (part no.; serial no.)
Type: ACU 401 – 09 ; Serial No.: 06053980
5.4.0
Version: 5.4.0 ; Software: 15 000 190
(C) 2013 BONFIGLIOLI VECTRON
Settings
Min.
0
Optional
Inverter
27 can be
Set password
Max.
Fact. sett.
999
0
06/13
Need help?
Do you have a question about the ACTIVE Cube ACU 201-01 and is the answer not in the manual?
Questions and answers
Конфигурация 610 контроллером крутящего момента. Опорный крутящий момент представлен в видепроцент и он передается в соответствующие эксплуатационные показателиприложение. Переключение между регулированием переменной скорости и регулированием крутящего моментаУправление осуществляется без рывков во время работ? Как подробнее узнать об этом режиме? Нужно обеспечить останов с заданным моментом на валу мотора