11 System Data

The various control functions and methods according to the selected
30 are supplemented by control and special functions. For monitoring the applica-
tion, process parameters are calculated from electrical control parameters.
11.1

Actual System Value

The parameter
via the actual value
The
Actual frequency
389 and can be read out via the parameter
factor
tual frequency
No.
389 Factor Actual Value System
11.2

Volume Flow and Pressure

The parameterization of the factors
Pressure
Pressure
trical control parameters.
Volume flow
case of the sensorless control methods. In the case of the field-oriented control
methods, they are referred to the torque-forming current component
No.
397 Nominal volumetric flow
398 Nominal pressure
Line mains or channel characteristic:
Point A in the figure describes the rating point of a pump. The transition to partial
load operation mode B1 can be affected at a constant pressure H (change of convey-
ing flow Q, pressure H remains constant). The transition to partial load operation
mode B2 can be affected according to the bad point method (change of pressure H
and conveying flow Q). Both methods can be realized with the integrated technology
controller in configurations 111, 211, 411 and 611. The actual values displayed are
calculated according to the bad point method independently of the selected
tion mode
Operating Instructions ACU
06/13
Actual system value factor
Actual system value
241 to be monitored is multiplied by the
241 x
Actual system value factor
Parameter
Description
398 is necessary if the matching actual values
286 are used to monitor the drive. The conversion is done using the elec-
285 and
286 are referred to the
Pressure
Parameter
Description
H
B1
kPa
B2
440 of the technology controller.
389 can be used if the drive is monitored
242.
Actual system value
389 =
Actual system value
Settings
Min.
Max.
-100.000
100.000
Nominal Volumetric Flow
Volumetric Flow
Effective current
Settings
Min.
Max.
3
1 m
/h
99999 m
0.1 kPa
999.9 kPa
P
- method
const.
A
bad point method
Configuration
Actual system value
242, i.e.
Ac-
242.
Fact. sett.
1.000
397 and
Nominal
285 and
214 in the
216.
Isq
Fact. sett.
3
3
/h
10 m
/h
100.0 kPa
Q
3
m /h
Opera-
133

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ACTIVE Cube ACU 201-01 and is the answer not in the manual?

Questions and answers

Владимир
February 17, 2025

Конфигурация 610 контроллером крутящего момента. Опорный крутящий момент представлен в видепроцент и он передается в соответствующие эксплуатационные показателиприложение. Переключение между регулированием переменной скорости и регулированием крутящего моментаУправление осуществляется без рывков во время работ? Как подробнее узнать об этом режиме? Нужно обеспечить останов с заданным моментом на валу мотора

Subscribe to Our Youtube Channel

Table of Contents

Save PDF