Frequency inverter 230 v / 400 v 0.25 kw ... 132 kw
Table of Contents

Advertisement

No.
435 Operation mode
436 Acceleration Time
437 Deceleration Time
438 Traverse Amplitude
439 Proportional Step
440 Operation mode
441 Fixed frequency
442 max. P component
443 Hysteresis
444 Amplification
445 Integral time
446 Ind. volume flow control factor
447 1. blocking frequency
448 2. blocking frequency
449 Frequency hysteresis
450 Tolerance band
451 Filter Time Constant
452 Operation mode
453 Error/warning behavior
454 Point X1
455 Point Y1
456 Point X2
457 Point Y2
458 Operation mode
459 Signal source
460 Positioning distance
461 Signal correction
462 Load correction
463 Activity after positioning
464 Waiting time
465 Operation mode
466 Temperature coefficient
467 Adjusting temperature
469 Reference orientation
471 Positioning frequency
472 Max. positional error
473 Ramp Keypad Motorpoti
474 Operation mode
475 Reference frequency source
476 Reference percentage source
280
Traverse function
Description
Technology Controller
Block Frequencies
Multifunctional input 1
Positioning
Temperature Adjustment
Positioning
Motor Potentiometer
Frequency reference channel
Reference percentage channel
Operating Instructions ACU
Unit
Setting range
-
Selection
s
0.01 ... 320.00
s
0.01 ... 320.00
%
0.01 ... 50.00
%
0.01 ... 50.00
-
Selection
Hz
-999.99 ... 999.99
Hz
0.01 ... 999.99
%
0.01 ... 100.00
-
-15.00 ... 15.00
ms
0 ... 32767
-
0.10 ... 2.00
Hz
0.00 ... 999.99
Hz
0.00 ... 999.99
Hz
0.00 ... 100.00
%
0.00 ... 25.00
ms
Selection
-
Selection
-
Selection
%
0.00 ... 100.00
%
-100.00 ... 100.00
%
0.00 ... 100.00
%
-100.00 ... 100.00
-
Selection
-
Selection
6
U
0.000 ... 1 10
ms
-327.68 ... 327.67
-
-32768 ... 32767
-
Selection
6
ms
0 ... 3.6 10
-
Selection
%/100
0.00 ... 300.00
deg.C
-50.0 ... 300.0
°
0.0 ... 359.9
Hz
1.00 ... 50.00
°
0.1 ... 90.0
Hz/s
0.01 ... 999.99
-
Selection
-
Selection
-
Selection
Chapter
18.8
18.8
18.8
18.8
18.8
17.3
17.3
17.3
17.3
17.3
17.3
17.3
14.9
14.9
14.9
15.1.1.3
15.1.1.4
15.1
15.1.1.5
15.1.1.1
15.1.1.1
15.1.1.1
15.1.1.1
12.6
12.6.1
12.6.1
12.6.1
12.6.1
12.6.1
12.6.1
18.7.2
18.7.2
18.7.2
12.6.2
12.6.2
12.6.2
14.10.3
14.10
14.4
14.5
06/13

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ACTIVE Cube ACU 201-01 and is the answer not in the manual?

Questions and answers

Владимир
February 17, 2025

Конфигурация 610 контроллером крутящего момента. Опорный крутящий момент представлен в видепроцент и он передается в соответствующие эксплуатационные показателиприложение. Переключение между регулированием переменной скорости и регулированием крутящего моментаУправление осуществляется без рывков во время работ? Как подробнее узнать об этом режиме? Нужно обеспечить останов с заданным моментом на валу мотора

Table of Contents

Save PDF