4.3

ACU 201 (0.25 to 1.1 kW, 230 V)

Type
ACU 201
Construction Size
Output, motor side
Recommended motor shaft power
Output current
Long-term overload current (60 s)
Short-time overload current (1 s)
Output voltage
Protection
Rotary field frequency
Switching frequency
Output, brake resistor
Min. brake resistance
Recommended brake resistor
(U
= 385 V)
dBC
Input, mains side
3)
Mains current
3ph/PE
1ph/N/PE; 2ph/PE
Mains voltage
Mains frequency
Fuse 3ph
1ph/N; 2ph
UL type 250 VAC RK5, 3ph
1ph/N; 2ph
Mechanics
Dimensions
Weight (approx.)
Degree of protection
Terminals
Form of assembly
Ambient conditions
Energy dissipation (2 kHz switching
frequency)
Coolant temperature
Storage temperature
Transport temperature
Rel. air humidity
If required by the customer, the switching frequency may be increased if the output current is reduced at the
same time. Comply with the applicable standards and regulations for this operating point.
6)
Output current
Frequency inverter nominal power
0.25 kW
0.37 kW
0.55 kW
0.75 kW
1.1 kW
1)
Three-phase connection requires a commutating choke.
2)
One- and two-phase connection requires a commutating choke.
3)
Mains current with relative mains impedance ≥ 1% (see chapter "Electrical installation")
4)
Maximum output current = 9.5 A with single-phase and two-phase connection
5)
Reduction of switching frequency in thermal limit range
6)
Maximum current in continuous operation
7)
The device for single phase connection is not listed in the product catalogue and only available on request.
32
-01
P
kW
0.25
I
A
1.6
I
A
3.2
I
A
3.2
U
V
Maximum input voltage, three-phase
-
-
f
Hz
0 ... 1000, depending on switching frequency
f
kHz
R
Ω
100
R
Ω
430
1.6
I
A
2.9
U
V
f
Hz
6
I
A
6
6
I
A
6
HxWxD mm
m
kg
-
-
2
A
mm
-
-
P
W
32
T
°C
n
T
°C
L
T
°C
T
-
%
Switching frequency
2 kHz
4 kHz
1.6 A
1.6 A
2.5 A
2.5 A
3.0 A
3.0 A
4.0 A
4.0 A
2)
2) 5)
5.4 A
5.4 A
Operating Instructions ACU
-03
-05
-07
1
0.37
0.55
0.75
2.5
3.0
4.0
5.0
4.5
6.0
5.0
6.0
8.0
Short circuit / earth fault proof
2, 4, 8, 12, 16
100
100
100
300
230
160
2.5
3
4
4.5
5.4
7.2
184 ... 264
45 ... 66
6
10
6
10
190 x 60 x 175
1.2
IP20 (EN60529)
0.2 ... 1.5
Vertical
38
43
53
0 ... 40 (3K3 DIN IEC 721-3-3)
-25 ... 55
-25 ... 70
15 ... 85; not condensing
8 kHz
12 kHz
1.6 A
1.3 A
2.5 A
2.1 A
3.0 A
2.5 A
4.0 A
3.4 A
2) 5)
2) 5)
5.4 A
4.5 A
-09
1.1
5)
5.4
7.3
8.0
100
115
1)
5.5
2)
9.5
10
16
10
15
73
16 kHz
1.1 A
1.7 A
2.0 A
2.7 A
5)
3.7 A
06/13

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ACTIVE Cube ACU 201-01 and is the answer not in the manual?

Questions and answers

Владимир
February 17, 2025

Конфигурация 610 контроллером крутящего момента. Опорный крутящий момент представлен в видепроцент и он передается в соответствующие эксплуатационные показателиприложение. Переключение между регулированием переменной скорости и регулированием крутящего моментаУправление осуществляется без рывков во время работ? Как подробнее узнать об этом режиме? Нужно обеспечить останов с заданным моментом на валу мотора