Code
01
04
F12
05
00
F13
01
10
01
02
07
21
22
23
24
30
31
32
33
34
F14
35
36
37
50
54
4n
5n
F14
6n
7n
8n
F14
9n
Table "Fault Messages" continued on next page.
266
Safety function STO
Diagnosis error of function STO; at least one of the shut-down paths
STOA and STOB is defective. Check units connected to shut-down
paths; check cabling and EMC.
Software self-diagnosis has detected an internal error. Consult BON-
FIGLIOLI customer service.
Fault message of 5-second monitoring. Shut-down paths STOA and
STOB were not actuated at the same time, but with an offset of more
than 5 seconds. Check addressing of shut-down paths or control of
protective circuitry.
Motor Connection
Earth fault on output, check motor and wiring.
Set
IDC compensation limit
increase limit, if necessary.
Minimum current monitoring, check motor and wiring.
Control Connection
Reference value on multifunctional input 1 faulty, check signal.
Reference value EM-S1INA faulty, check signal.
Overcurrent on multifunctional input 1, check signal.
Resolver fault. Check resolver connection and speed.
Resolver counting fault. Check resolver connection.
Resolver pole pair number incorrect. Check parameter of pole pairs.
Resolver connection fault. Check resolver connection.
Encoder signal defective, check connections S4IND and S5IND.
One track of the speed sensor signal is missing, check connections.
Direction of rotation of speed sensor wrong, check connections.
Encoder 2: Division Marks Fault. Check encoder settings.
Too less Division Marks Fault. Check encoder settings.
Too many Division Marks Fault. Check encoder settings.
Encoder 1: Division Marks Fault. Correct
er 1; refer to chapter 10.4.2 "Division marks, speed sensor 1".
The encoder is disabled. In configurations 210, 211 and 230 an encoder
must be activated. Set parameter
tion mode (not to "0 – off). If an expansion module is installed and
parameter
Actual Speed source
parameter
Operation Mode
evaluation mode.
KTY Temperature Measurement Failure. Check KTY connection.
External error; drive responded according to parameter setting for
535. Error was triggered via the logic signal or
eration mode ext. error
digital input signal assigned to parameter
Positioning
Positioning function fault. Please check Application manual Positioning.
EM-ABS-01 Module
Fault with Absolute encoder evaluation. Please check EM-ABS-01 manu-
al.
Operating Instructions ACU
Meaning
415 reached, check motor and cabling,
Division Marks
490 to an evalua-
Operation Mode
766 is set to "2 – Speed Sensor 2",
493 (speed sensor 2) must be set to an
External error
491 of encod-
Op-
183.
06/13
Need help?