15.2.1.1
Output Characteristic
The voltage range of the output signal at multifunction output 1 can be adjusted. The
value range of the actual value selected via parameter
assigned to the value range of the output signal which is adjusted via the parameters
Voltage 100%
No.
551 Voltage 100%
552 Voltage 0%
Analog Operation
value:
+24V
+10V
0V
0%
With the parameters
100% and 0% of the output parameter is set. If the output value exceeds the refer-
ence value, the output voltage also exceeds the value of the parameter
551 up to the maximum value of 24V.
100%
178
551 and
552.
Voltage 0%
Parameter
Description
553 with abs. act.
50%
100%
551 and
Voltage 100%
Operating Instructions ACU
Analog operation
Settings
Min.
Max.
0.0 V
22.0 V
0.0 V
24.0 V
553 with signs:
Analog operation
+24V
+10V
+5V
0V
-100%
0%
552, the voltage range at
Voltage 0%
553 is
Fact. sett.
10.0 V
0.0 V
100%
Voltage
06/13
Need help?