269 Warnings
273 Application Warnings
275 Controller Status
277 STO Status
278 Frequency MFO1F
Additional to the described Actual values further Actual values are available for Fieldbus
access. These are notable parameters
tion Warnings
code (and without text). Please refer to the Communication manuals.
The actual values can be read out and monitored in the VAL menu branch of the oper-
ating unit. The parameter
selection of the actual value parameters.
The digital inputs may seem deactivated in the actual value display 243, 250 (con-
stant "0"). This can be caused by the used configuration or used functions (in example
encoder or frequency input).
258
Actual Values of the Frequency Inverter
Warning message with error code and abbreviation.
Application Warning message with error code and
abbreviation.
The reference value signal is limited by the controller
coded in the controller status.
Signal state of the shutdown paths STOA (digital input
S1IND/STOA) and STOB (S7IND/STOB) of the safety
function "STO – Safe Torque Off".
Output signal on multifunctional input 1 in
mode
,
274
in which the respective feedback can be readout as a hexadecimal
Operation level
Input
Deactivation mechanism for Actual value display
S2IND
S4IND
Track B (Encoder 1)
S5IND
Track A (Encoder 1)
S6IND
Track Z (Encoder 1) or
MFI1
Analog input
Settings:
For Encoder 1, check Parameter
For PWM / Rep. Freq. input, check Parameter
For MFI1 check Parameter
Actual value:
Encoder 1: Frequency is displayed in 217, speed in 218.
PWM / Rep. freq. input: PWM is displayed in 258, frequency in 252.
Operating Instructions ACU
550 – repetition frequency.
,
260
Current error
Warnings
28 in the PARA menu branch defines the
PWM / Rep. freq. input
PWM / Rep. freq. input
Operation mode
Operation mode
452.
Operation mode
Operation
270 and
Applica-
490.
496.
06/13

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ACTIVE Cube ACU 201-01 and is the answer not in the manual?

Questions and answers

Владимир
February 17, 2025

Конфигурация 610 контроллером крутящего момента. Опорный крутящий момент представлен в видепроцент и он передается в соответствующие эксплуатационные показателиприложение. Переключение между регулированием переменной скорости и регулированием крутящего моментаУправление осуществляется без рывков во время работ? Как подробнее узнать об этом режиме? Нужно обеспечить останов с заданным моментом на валу мотора

Table of Contents

Save PDF