8. Ensure AUTO HEIGHT icon (A) appears on monitor
and is displayed as shown at (B). When header is set
for cutting on ground, this verifies that combine is
correctly using potentiometer on header to sense
ground pressure.
NOTE:
AUTO HEIGHT field (B) may appear on any of RUN
tabs and not necessarily on RUN 1 tab.
9. Select CALIBRATION on combine display, and press
right arrow navigation key to enter information box.
10. Select HEADER (A), and press ENTER. The
CALIBRATION dialog box opens.
NOTE:
You can use up and down navigation keys to move
between options.
11. Follow calibration steps in order in which they appear in
dialog box. As you proceed through calibration process,
display will automatically update to show next step.
NOTE:
Pressing ESC key during any of steps or letting system
sit idle for more than three minutes will cause
calibration procedure to stop.
NOTE:
Refer to your combine operator's manual for an
explanation of any error codes.
12. When all steps have been completed, CALIBRATION SUCCESSFUL message is displayed on page. Exit
CALIBRATION menu by pressing ENTER or ESC key.