New Holland Combines Cx/Cr Series (Cr Series - Model Year 2014 And Earlier); Checking Voltage Range From Combine Cab (New Holland) - MacDon FFT FD75 Assembly Instructions Manual

Flexdraper combine header with ca25 combine adapter
Table of Contents

Advertisement

5.1.14 New Holland Combines CX/CR Series (CR Series – Model Year 2014
and Earlier)
NOTE:
For New Holland CR models 6.80, 6.90, 7.90, 8.90, 9.90, and 10.90, refer to
Series – Model Year 2015 and Later), page

Checking Voltage Range from Combine Cab (New Holland)

NOTE:
Changes may have been made to the combine controls or display since this document was published. Refer to
combine operator's manual for updates.
CAUTION
Check to be sure all bystanders have cleared the area.
1. Position header 150 mm (6 in.) above ground, and unlock adapter float.
2. Check that float lock linkage is on down stops
(washer [A] and nut [B] cannot be moved) at both
locations.
NOTE:
If header is not on down stops during next two steps,
voltage may go out of range during operation causing a
malfunction of auto header height control (AHHC)
system.
3. Adjust cable take-up bracket (B) (if necessary) until
pointer (A) on float indicator is on 0.
4. Ensure header float is unlocked.
214325
SETTING UP AUTO HEADER HEIGHT CONTROL
260.
5.1.15 New Holland Combines (CR
Figure 5.240: Float Lock
Figure 5.241: Float Indicator Box (Most
Common 5 Volt AHHC Sensor
Assembly Shown)
250
Revision A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents