4.13 Adjusting Auger to Pan Clearance

DANGER
To avoid bodily injury or death from unexpected start-up of machine, always stop engine and remove key
from ignition before leaving operator's seat for any reason.
IMPORTANT:
Maintain an appropriate distance between auger and auger pan. Too little clearance may cause tines or flighting to
contact and damage feed draper or pan when operating header at certain angles. Look for evidence of contact
when greasing adapter.
1. Extend center-link to steepest header angle, and position header 150–254 mm (6–10 in.) off the ground.
2. Lock header wings.
3. Shut down combine and remove key from ignition.
4. Ensure float lock linkage is on down stops (washer [A]
and nut [B] cannot be moved) at both locations.
5. Ensure lower end of linkage bars (A) are against
studs (B) at both ends of auger.
214325
PERFORMING PREDELIVERY CHECKS
119
Figure 4.64: Float Lock
Figure 4.65: Linkage Bars
Revision A