Replacing Auto Header Height Control (AHHC) Sensor

The auto header height control (AHHC) sensor/potentiometer sends a signal to combine allowing it to maintain a
cutting height and optimize float as header follows ground contours. To replace AHHC sensor, follow these steps:
1. Disconnect wiring harness from existing sensor (A).
2. Remove two nuts and bolts (B) that secure sensor to
bracket and remove sensor (A).
IMPORTANT:
To avoid damaging new sensor, install sensor as
follows:
3. Position sensor control arm (A) against stop (B).
4. Install new sensor (C) onto linkage arm with wiring plug
facing away from stop.
5. Pretension sensor's internal spring by rotating
sensor (C) until bolt holes align with holes on bracket.
6. Secure new sensor (A) to bracket with two nuts and
bolts (B).
214325
SETTING UP AUTO HEADER HEIGHT CONTROL
203
Figure 5.135: AHHC Sensor
Figure 5.136: AHHC Sensor
Figure 5.137: AHHC Sensor