VLT Automation VT Drive FC322
Programming Guide
[65]
Comparator 5
[70]
Logic rule 0
[71]
Logic rule 1
[72]
Logic rule 2
[73]
Logic rule 3
[74]
Logic rule 4
[75]
Logic rule 5
[80]
SL digital output A
[81]
SL digital output B
[82]
SL digital output C
[83]
SL digital output D
[84]
SL digital output E
[85]
SL digital output F
[160]
No alarm
[161]
Running reverse
[165]
Local ref active
[166]
Remote ref active
[167]
Start command act.
[168]
Hand mode
Remote Site Products - 1-888-532-2706 - www.remotesiteproducts.com
http://www.remotesiteproducts.com/p-20772-Danfoss-131X8135-VLT-Automation-VT-Drive-VFD-FC322-230V-5-HP.aspx
See par. group LC-1#. If Comparator 5 is evaluated as TRUE, the output will go high. Otherwise, it
will be low.
See par. group LC-4#. If Logic Rule 0 is evaluated as TRUE, the output will go high. Otherwise, it
will be low.
See par. group LC-4#. If Logic Rule 1 is evaluated as TRUE, the output will go high. Otherwise, it
will be low.
See par. group LC-4#. If Logic Rule 2 is evaluated as TRUE, the output will go high. Otherwise, it
will be low.
See par. group LC-4#. If Logic Rule 3 is evaluated as TRUE, the output will go high. Otherwise, it
will be low.
See par. group LC-4#. If Logic Rule 4 is evaluated as TRUE, the output will go high. Otherwise, it
will be low.
See par. group LC-4#. If Logic Rule 5 is evaluated as TRUE, the output will go high. Otherwise, it
will be low.
SL Controller Action
See par. 13-52
. The output will go high whenever the Logic Action [38]
out. A high
is executed. The output will go low whenever the Logic Action [32] Set dig. out. A low
is executed.
SL Controller Action
See par. 13-52
. The input will go high whenever the Logic Action [39]
out. A high
is executed. The input will go low whenever the Logic Action [33]
executed.
See par. 13-52
SL Controller Action
. The input will go high whenever the Logic Action [40]
out. A high
is executed. The input will go low whenever theLogic Action [34]
executed.
See par. 13-52
SL Controller Action
. The input will go high whenever the Logic Action [41]
out. A
high is executed. The input will go low whenever the Logic Action [35]
executed.
See par. 13-52
SL Controller Action
. The input will go high whenever the Logic Action [42]
out. A high
is executed. The input will go low whenever the Logic Action [36]
executed.
SL Controller Action
See par. 13-52
. The input will go high whenever the Logic Action [43]
out. A high
is executed. The input will go low whenever the Logic Action [37]
executed.
Output is high when no alarm is present.
Output is high when the frequency converter is running counter clockwise (the logical product of
the status bits 'running' AND 'reverse').
Reference Site
Output is high when par. 3-13
Linked to hand auto
at the same time as the LCP is in Hand mode.
Output is high when par. 3-13
Reference Site = Remote
LCP is in [Auto] mode.
Output is high when there is an active Start command (i.e. via digital input bus connection or [Hand]
or [Auto]), and no Stop or Start command is active.
Output is high when the frequency converter is in Hand mode (as indicated by the LED light above
[Hand]).
MG.20.W1.22 - VLT is a registered Danfoss trademark
2 Parameter Description
Set dig. out. A low
Set dig. out. A low
Set dig. out. A low
Set dig. out. A low
Set dig. out. A low
Reference Site
= [2] Local or when par. 3-13
[1] or
Linked to hand/auto
[0] while the
2
Set dig.
Set dig.
is
Set dig.
is
Set dig.
is
Set dig.
is
Set dig.
is
= [0]
85