2 Parameter Description
0-38 Display Text 2
Range:
0*
[0 - 0 ]
2
0-39 Display Text 3
Range:
0*
[0 - 0 ]
2.2.6 0-4* LCP Keypad
Enable, disable and password protect individual keys on the LCP.
0-40 [Hand on] Key on LCP
Option:
[0]
Disabled
[1] *
Enabled
[2]
Password
[3]
Hand Off/On
[4]
Hand Off/On w. Passw.
0-41 [Off] Key on LCP
Option:
[0]
Disabled
[1] *
Enabled
[2]
Password
[3]
Hand Off/On
[4]
Hand Off/On w. Passw.
34
Remote Site Products - 1-888-532-2706 - www.remotesiteproducts.com
http://www.remotesiteproducts.com/p-20772-Danfoss-131X8135-VLT-Automation-VT-Drive-VFD-FC322-230V-5-HP.aspx
Function:
In this parameter it is possible to write an individual text string for display in the LCP or to be read
via serial communication. If to be displayed permanently select Display Text 2 in par. 0-20
Line 1.1 Small
, par. 0-21
Display Line 1.2 Small
Line 2 Large
or par. 0-24
Display Line 3 Large
character. Use the
and
buttons to move the cursor. When a character is highlighted by the
cursor, this character can be changed. A character can be inserted by placing the cursor between
two characters and pressing
or
.
Function:
In this parameter it is possible to write an individual text string for display in the LCP or to be read
via serial communication. If to be displayed permanently select Display Text 3 in par. 0-20
Line 1.1 Small
Display Line 1.2 Small
,par. 0-21
Line 2 Large
or par. 0-24
Display Line 3 Large
character. Use the
and
buttons to move the cursor. When a character is highlighted by the
cursor, this character can be changed. A character can be inserted by placing the cursor between
two characters and pressing
or
.
Function:
No function
[Hand on] Key enabled
Avoid unauthorized start in Hand mode. If par. 0-40
Personal Menu, then define the password in par. 0-65
the password in par. 0-60
Main Menu Password
Function:
No function
[Off] Key is enabled
[Off] Key on LCP
Avoid unauthorized stop. If par. 0-41
Personal Menu, then define the password in par. 0-65
Password. Otherwise define the password in par. 0-60
word.
MG.20.W1.22 - VLT is a registered Danfoss trademark
VLT Automation VT Drive FC322
Programming Guide
, par. 0-22
Display Line 1.3 Small
, par. 0-23
. Use the
or
buttons on the LCP to change a
Display Line 1.3 Small
, par. 0-22
, par. 0-23
. Use the
or
buttons on the LCP to change a
[Hand on] Key on LCP
is included in the My
Personal Menu Password
. Otherwise define
.
0-41 [Off] Key on LCP is included in the My
Personal Menu Password
0-65 Personal Menu
Main Menu Password
0-60 Main Menu Pass-
Display
Display
Display
Display

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vlt dc 322

Table of Contents