Danfoss VLT Automation VT Drive FC 322 Programming Manual page 12

Hide thumbs Also See for VLT Automation VT Drive FC 322:
Table of Contents

Advertisement

1 How to Programme
The parameter shortcut
can be carried out by holding down the [Main Menu] key for 3 seconds. The parameter shortcut allows direct access to any parameter.
1
1.1.2 Quick Transfer of Parameter Settings between Multiple Frequency Converters
Once the set-up of a frequency converter is complete, we recommend
that you store the data in the LCP or on a PC via MCT 10 Set-up Software
Tool.
Data storage in LCP:
1.
Go to par. 0-50
LCP Copy
2.
Press the [OK] key
3.
Select "All to LCP"
4.
Press the [OK] key
All parameter settings are now stored in the LCP indicated by the progress bar. When 100% is reached, press [OK].
NB!
Stop the motor before performing this operation.
You can now connect the LCP to another frequency converter and copy the parameter settings to this frequency converter as well.
Data transfer from LCP to frequency converter:
1.
Go to par. 0-50
LCP Copy
2.
Press the [OK] key
3.
Select "All from LCP"
4.
Press the [OK] key
The parameter settings stored in the LCP are now transferred to the frequency converter indicated by the progress bar. When 100% is reached, press
[OK].
10
Remote Site Products - 1-888-532-2706 - www.remotesiteproducts.com
http://www.remotesiteproducts.com/p-20772-Danfoss-131X8135-VLT-Automation-VT-Drive-VFD-FC322-230V-5-HP.aspx
MG.20.W1.22 - VLT is a registered Danfoss trademark
VLT Automation VT Drive FC322
Programming Guide

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vlt dc 322