Configuring a PTP Master Boundary Clock

244
(Optional) Configure the priority value of the clock (0 through 255). This value is used
7.
in selecting the best master clock. The priority1-value is advertised in the master clock's
announce message to clock clients. The default value is 128.
[edit protocols ptp]
user@host# set priority1 priority1-value
(Optional) Configure the tie-breaker in selecting the best master clock (0 through
8.
255). The
priority2
value differentiates and prioritizes the master clock to avoid
confusion when the
priority1-value
The default value is 128.
[edit protocols ptp]
user@host# set priority2 priority2-value
Specify the PTP slave clock parameters.
9.
[edit protocols ptp]
user@host# set slave
For information about configuring the slave clock options, see
Slave Clock" on page
254.
(Optional) Enable unicast negotiation. Unicast negotiation is a method by which the
10.
announce, synchronization, and delay response packet rates are negotiated between
the master clock and the clock client before a PTP session is established.
[edit protocols ptp]
user@host# set unicast-negotiation
NOTE:
Unicast negotiation, when enabled, does not allow you to commit
packet rate–related configurations.
IEEE 1588v2 PTP Boundary Clock Overview on page 234
Configuring a PTP Master Boundary Clock on page 244
Configuring a PTP Slave Clock on page 254
Example: Configuring a PTP Boundary Clock With Unicast Negotiation on page 250
Example: Configuring a PTP Boundary Clock on page 248
A Precision Time Protocol (PTP) master boundary clock sends PTP messages to the
clients (ordinary and boundary) so that they can establish their relative time offset from
this master's clock or clock reference. You cannot configure an ordinary master clock on
a device. The master boundary clock synchronizes time through a boundary slave port.
To configure a master boundary clock, you must include the
is the same for different master clocks in a network.