Juniper ACX1000 Configuration Manual page 491

Junos os; acx series universal access router
Hide thumbs Also See for ACX1000:
Table of Contents

Advertisement

Copyright © 2017, Juniper Networks, Inc.
The following statements must be explicitly configured:
lldp-configuration-notification-interval
3600 seconds. There is no default value.
ptopo-configuration-trap-interval
2147483647 seconds. There is no default value.
To disable LLDP on all or a particular interface, include the
hierarchy level:
[edit protocols lldp]
interface (all | interface-name) {
disable;
}
To disable LLDP on all interfaces, use the
interface, include the
disable
NOTE:
The interface-name must be the physical interface (for example,
ge-1/0/0) and not a logical interface (unit).
The advertisement interval determines the frequency that an LLDP interface sends LLDP
advertisement frames. The default value is 30 seconds. The allowable range is from 5
through 32768 seconds. You adjust this parameter by including the
statement at the
[edit protocols lldp]
The hold multiplier determines the multiplier to apply to the advertisement interval. The
resulting value in seconds is used to cache learned LLDP information before discard. The
default value is 4. When used with the default advertisement interval value of 30 seconds,
this makes the default cache lifetime 120 seconds. The allowable range of the hold
multiplier is from 2 through 10. You adjust this parameter by including the
statement at the
[edit protocols lldp]
The transmit delay determines the delay between any two consecutive LLDP
advertisement frames. The default value is 2 seconds. The allowable range is from 1
through 8192 seconds. You adjust this parameter by including the
statement at the
[edit protocols lldp]
The physical topology configuration maximum hold time determines the time interval
for which an agent device maintains physical topology database entries. The default
value is 300 seconds. The allowable range is from 1 through 2147483647 seconds. You
adjust this parameter by including the
at the
[edit protocols lldp]
The LLDP configuration notification interval determines the period for which trap
notifications are sent to the SNMP Master Agent when changes occur in the database
of LLDP information. This capability is disabled by default. The allowable range is from 0
(disabled) through 3600 seconds. You adjust this parameter by including the
lldp-configuration-notification-interval
level.
Chapter 12: Configuring Layer 2 Control Protocol
—The allowable range is from 0 through
—The allowable range is from 1 through
all
option. To disable LLDP on a particular
statement with the interface name.
hierarchy level.
hierarchy level.
hierarchy level.
ptopo-configuration-maximum-hold-time
hierarchy level.
statement at the
statement at the
interfaces
advertisement-interval
hold-multiplier
transmit-delay
statement
[edit protocols lldp]
hierarchy
433

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Acx5048Acx5096Acx500Acx1100Acx2000Acx2100 ... Show all

Table of Contents