OWNER_PW
A password for owner presets protection is defined
OWNER_ID
The owner is identified by password, manipulation of owner presets is possible (can be cleared by
command)
AES_OK
Die AES/EBU Schnittstelle ist in Ordnung
AESINPUT
Es wird das Audio-Signal der AES/EBU Schnittstelle statt dem Audio-Signal am analogen Eingang
verwendet
CANADDR
Die CAN-Adresse wurde per Software gewählt, die Adress-Einstellung an der Blende des RCM-26 wird
ignoriert

Input Channel State Flags

Flag
Description
PILOT
The 19 kHz pilot tone is not detected above threshold

Output Channel State Flags

Flag
Description
PSOVL
The SMPS reports overload
HFDET
The power amplifier reports excessive HF level
SHORTED
A low impedance load or short-circuit is detected
THERMPROT
The amplifier's thermal protection is active (protect-mode)
PROTECT
In general: protect-mode active
AMPFAIL
A amplifier failure was detected (output is muted via relay off)
MUTE
The output is muted via relay off
GNDFLT
A ground fault has occurred
GAINRED
The amplifier's gain reduction is active (protect-mode)
DISHI
Rail voltage: step high disabled
DISMID
Rail voltage: step mid disabled
Z_VALID
The calculated load value (U/I) is actually valid
Z_MIN
The load is below minimum, shorted
Z_MAX
The load is above maximum, open
PILOT
The 19 kHz pilot tone is not detected above threshold
MEAS
The sweep measurement is active
THRM_HDRM
The thermal headroom is below minimum