IRIS-Net
DEVICE
CONFIGURATION
WATCHDOG
BOOT COUNT
AUDIO PROCESSING Error during the processing of audio data.
MEMORY/DATA
SUPPLY VOLTAGE
AD CONVERTER
TEMPERATURE
FAN SPEED
TEMP
USER FLAGS
CAN BUS
COBRANET
HEARTBEAT FROM
MASTER
HEARTBEAT CHECK
SLAVE DEVICE
REMOTE
AMPLIFIERS
GPI
DPM 4000
RS-232 PORTS
Bosch Security Systems B.V.
At the occurrence of a type of error for which the checkbox DETECT is ticked, the COLLECTED
ERROR STATE flag is set at the same time. The FAULT-LED on the front panel of the P 64 lights
and the FAULT relay opens.
Detected types of errors for which the checkbox HOLD is ticked are stored. Sporadic errors
are indicated until the feature is reset using the CLEAR button.
Error in the hardware configuration of the P 64. Pressing the INFO button reveals more
detailed information concerning the error.
The Watchdog of the P 64 was activated. Press the CLEAR button to clear this error indication.
Indicates the number of resets caused by the watchdog. Press the RESET button to reset the
number to 0.
Memory or Read/Write error.
Error in the internal power supply unit.
Malfunction of the control inputs' A/D converters.
Temperature overload of the P 64.
Current running speed of the P 64's fan. Possible fan speeds are Off, Slow, Med. and High, see
table below.
Current temperature on the inside of the enclosure.
One or more User Flags have been set. CONFIG button for configuring User Flags.
Fault condition on the CAN-Bus. The CONFIG button opens the CAN Interface Faults dialog,
see below.
Fault condition on the CobraNet. Further details are provided via the CobraNet dialog box.
Query from the master P 64, which has been programmed to monitor this P 64, are not
received anymore.
Select this checkbox to check for heartbeat messages from other N8000s.
At least one P 64 that had to be monitored does not react anymore. The CONFIG button opens
a list of P 64 that have been configured as Slave devices.
A connected Remote Amplifier has transferred an error message. The CONFIG button opens
the CAN Interface Faults dialog, see below.
The input voltage at a control input (GPI) is too high/low.
The DYNACORD DPM 4000 that is connected via RS-232 port cannot be reached anymore.
Malfunction has been detected for an external device, which is being monitored via RS-232
port.