IRIS-Net

Control Port

A control port offering two control inputs and two control outputs is located on the amplifier's rear panel. The
functions of these inputs and outputs can be programmed in a variety of ways. For example, the control inputs (GPI)
can be used for power-on / stand-by or preset switching as well as for changing parameters. The control outputs (GPO)
are for signaling internal statuses. They can directly trigger LEDs, control lamps or relays. In the Supervision & Test
window the states of the control inputs are displayed and you have the possibility to switch the control outputs
manually. For more information and electrical specifications of the control port, please refer to the amplifier's manual.
Control Inputs: Each status change of a control input can trigger a function. Different functions can be assigned for the
opening (OFF) or closing (ON) of a contact.
Example:
This example shows the programming of two control inputs where IN1 switches the amplifier on or off and IN2 selects
presets U02 or U03.
IN1 ON: Power on (closing the contact of control input 1 switches the amplifier on)
IN1 OFF: Power off (opening the contact of control input 1 switches the amplifier to stand-by)
IN2 ON: Preset U03 (closing the contact of control input 2 selects preset U03)
IN2 OFF: Preset U02 (opening the contact of control input 2 selects preset U02)
Element
Default
(empty)
(empty)
(empty)
0 ms
Control Outputs: Internal status changes inside of the amplifier, such as operational faults, alerts when exceeding
parameter limits, and internal operational statuses can be signaled to external systems or central control units.
Example:
Bosch Security Systems B.V.
Range
Description
IN 1 ON
This provides a listing of the two control inputs and their statuses ON and OFF.
IN 1 OFF
The entries in the corresponding lines specify the action when closing (ON) or
IN 2 ON
opening (OFF) a contact.
IN 2 OFF
This column allows assigning functions to a control input's statuses. Clicking
the desired line in the Function menu opens a dialog field that shows all
accessible functions. The table "Input and Receive Job Functions" lists all func-
tions together with their individual settings.
Here you can set the different function parameters. For more information,
please refer to the table "Input and Receive Job Functions".
Certain functions allow specifying optional parameter values.
0...10027 ms
Here you can program delay or debouncing times. Following a status change
16.33 ms
the assigned function is initiated after the set time interval has past.
Steps
User Manual
REMOTE AMPLIFIER | en
2017.05 | 3.20 | F.01U.119.956