Summary of Contents for Bosch ICP-AMAX4-P2-EN

  • Page 1 AMAX panel 4000 / AMAX panel 4000 EN ICP-AMAX4-P1 / ICP-AMAX4-P2-EN / ICP-AMAX4-P3-EN Quick Start Guide...
  • Page 3: Table Of Contents

    Reset to Factory Default Settings LCD Menu Programming Address Programming 4.4.1 Communication and Report Setting 4.4.2 Zone Programming 4.4.3 Output Programming 4.4.4 Access Codes 4.4.5 System Programming Troubleshooting Technical Data Bosch Sicherheitssysteme GmbH Quick Start Guide 2013.07 | 03 | F.01U.267.113...
  • Page 4: Short Information

    ICP-KP8L-Icon LCD keypad. As the system includes a large number of programmable functions and options, we suggest reading the complete installation manual. For detailed operation method, please refer to the User Guide. 2013.07 | 03 | F.01U.267.113 Quick Start Guide Bosch Sicherheitssysteme GmbH...
  • Page 5: System Overview

    AMAX panel 4000 / AMAX panel 4000 System overview | en System overview Information: Customer: Location: Account #: Installer: Date: Bosch Sicherheitssysteme GmbH Quick Start Guide 2013.07 | 03 | F.01U.267.113...
  • Page 6: Wiring Diagram

    100 Ω - 2,2 k RFRC-OPT 1= (1) Slow flash: Normal state On: Trouble state Off: Trouble state PO-5 1 Tamper Switch 2 Zone Switch 3 EOL 2,2 k 2013.07 | 03 | F.01U.267.113 Quick Start Guide Bosch Sicherheitssysteme GmbH...
  • Page 7: Installation

    Notice! The system must be installed and maintained by qualified installer / service person. Bosch recommends testing the whole alarm system at least once a week. Maintenance should be done by qualified installer / service person four times a year.
  • Page 8 D isp la y F W ve rsio n [9 ][9 ][9 ] + [# ] √ (only in A dres s P rogr. M ode) Figure 3.1: User Code Commands 2013.07 | 03 | F.01U.267.113 Quick Start Guide Bosch Sicherheitssysteme GmbH...
  • Page 9: Prerequisites For Certification Conform Installation

    The panel must be programmed with the EN settings indicated on the programming sheet. When the panel is set without EN parameters, the EN Indication (on Label) must be removed. Bosch Sicherheitssysteme GmbH Quick Start Guide 2013.07 | 03 | F.01U.267.113...
  • Page 10: Configuration

    – After entering programming mode, the system directly enters the programming data in the address 0000 (Receiver 1 telephone number or the initial digit of the IP address), then 2013.07 | 03 | F.01U.267.113 Quick Start Guide Bosch Sicherheitssysteme GmbH...
  • Page 11: Reset To Factory Default Settings

    Disconnect the AC power supply and backup battery to the control panel. Short-circuit the ‘Resetting to Factory Default’ pads. These set of pads are located at the top on the printed circuit board of the control panel. Bosch Sicherheitssysteme GmbH Quick Start Guide 2013.07 | 03 | F.01U.267.113...
  • Page 12: Lcd Menu Programming

    Use [▼] and [▲] to move main menus, submenus and secondary submenus up or down. Use [-] and [#] to move main menus, submenus and secondary submenus left or right. 2013.07 | 03 | F.01U.267.113 Quick Start Guide Bosch Sicherheitssysteme GmbH...
  • Page 13 COPY DATA TO KEY Figure 4.1: Menu Structure Warning! Programming parameters must be set within the value range in the programming address. Otherwise, the system will turn to indeterminate status. Bosch Sicherheitssysteme GmbH Quick Start Guide 2013.07 | 03 | F.01U.267.113...
  • Page 14 DUAL IP SETTING REMOTE ACCESS REM. ACCESS ARMED REMOTE PROGRAMMING RPC IP/PORT/DHCP IP ADDRESS PORT No DHCP UPDATE TIME:h DOMESTIC/CALLBACK CALLBACK SETTING DOMEST/CALLBACK No RING TIMES RING COUNT Figure 4.2: Com+Report 2013.07 | 03 | F.01U.267.113 Quick Start Guide Bosch Sicherheitssysteme GmbH...
  • Page 15 ZONE DOMESTIC ADD/DELETE ZONE INPUT ZONE No ZONE MODULE SEL. ZONE FUNCTION ZONE IN AREA PULSE COUNT DURAT. PULSE COUNT DURAT. CROSS TIMER CROSS ZN TIMER:sec Figure 4.4: Zone Setting Bosch Sicherheitssysteme GmbH Quick Start Guide 2013.07 | 03 | F.01U.267.113...
  • Page 16 KEYPAD IN AREA AREA TIMING INPUT AREA No EXIT DELAY: sec ENTRY DELAY: sec COMMON AREA COMMON AREA KP TONE/LOCKOUT KEYPAD ALARM TONE KEYPAD LOCK COUNT Figure 4.5: KP Area Setting 2013.07 | 03 | F.01U.267.113 Quick Start Guide Bosch Sicherheitssysteme GmbH...
  • Page 17 KP 2 BUTTON AL SYS TAMPER INDIC. SYS TAMP. ALL AR. FACTORY DEFAULT DEFAULT PANEL YES DEFAULT PANEL NO FUNCTION VIEW FAULT ANALYSIS FW VERSION Figure 4.6: System Setting Bosch Sicherheitssysteme GmbH Quick Start Guide 2013.07 | 03 | F.01U.267.113...
  • Page 18 OUTPUT AREA / ZONE OUTPUT MODE OUTPUT TIME: sec SIREN SETTINGS SIREN TIME: min SIREN BEEP ENABLE IN SIREN IND. EN SIREN OFF ON KEY Figure 4.7: Output Setting 2013.07 | 03 | F.01U.267.113 Quick Start Guide Bosch Sicherheitssysteme GmbH...
  • Page 19 CLR ALL RF DEVICES CLEAR CONFIRM CLEAR CANCEL Figure 4.8: RF Setting ADDRESS/KEY PROGR ADDRESS PROGRAM ADDR[ ]VALUE= COPY DATA TO PANEL COPY DATA TO KEY Figure 4.9: Address Key Program Bosch Sicherheitssysteme GmbH Quick Start Guide 2013.07 | 03 | F.01U.267.113...
  • Page 20: Address Programming

    Anti-replay for Receiver (0 = Disabled, 1 = Enabled) 0114 EN=1 Acknowledge Wait Time for Receiver (05 - 99 seconds) 0115 - 0116 Network Polling Time for Receiver (001 - 999 minutes) 0117 - 0119 2013.07 | 03 | F.01U.267.113 Quick Start Guide Bosch Sicherheitssysteme GmbH...
  • Page 21 Enter telephone number when the Contact ID or SIA format is selected; enter IP address and port number when the Bosch Network format is selected. Anti-replay for Receiver, Acknowledge Wait Time for Receiver and Network Polling Time for Receiver are valid only when using Bosch Network format.
  • Page 22 VDS-A EN=0 Siren / PO 1+2 Supervision Address 0140 Address Default 0 = disabled, 1 = PO1 enabled, 2 = PO2 enabled, 3 = 0140 VDS-A EN=3 PO1+2 enabled 2013.07 | 03 | F.01U.267.113 Quick Start Guide Bosch Sicherheitssysteme GmbH...
  • Page 23 RPC IP No 0162 - 0173 RPC Port Number 0174 - 0178 Control Panel DHCP Update Time (hours) 0179 RPC is the remote programming computer equipped with remote programming software. Bosch Sicherheitssysteme GmbH Quick Start Guide 2013.07 | 03 | F.01U.267.113...
  • Page 24 Default 0 = Disable, 1 = Enable 0197 Zone Pulse Count Duration Address 0198 - 0200 Address Default 0 = Disable, 1-999sec = Duration 0198 - 200 VDS-A EN=000 2013.07 | 03 | F.01U.267.113 Quick Start Guide Bosch Sicherheitssysteme GmbH...
  • Page 25 If the default 15 is set to the initial digit of the telephone number, domestic telephone alarm function is disabled; If set to other positions, it marks the end of the telephone number. Bosch Sicherheitssysteme GmbH Quick Start Guide 2013.07 | 03 | F.01U.267.113...
  • Page 26: Zone Programming

    Zone Type 0220 - 0221 Force Arm / Zone Bypass 0222 VDS-A EN=0/2 Silent Alarm / Chime Mode 0223 VDS-A EN=0/2 Zone Pulse Count 0224 VDS-A EN=0 Zone Lockout 0225 2013.07 | 03 | F.01U.267.113 Quick Start Guide Bosch Sicherheitssysteme GmbH...
  • Page 27 Zone Pulse Count 0254 VDS-A EN=0 Zone Lockout 0255 Zone Tamper (DEOL) 0256 Zone Status Report 0257 VDS-A EN=1/5/6/7 Unverified Alarm Report / Cross Zone 0258 VDS-A EN=0 Domestic No. 0259 Bosch Sicherheitssysteme GmbH Quick Start Guide 2013.07 | 03 | F.01U.267.113...
  • Page 28 Domestic No. 0289 Zone Function # 08 Address Default Zone Type 0290 - 0291 Force Arm / Zone Bypass 0292 VDS-A EN=0/2 Silent Alarm / Chime Mode 0293 VDS-A EN=0/2 2013.07 | 03 | F.01U.267.113 Quick Start Guide Bosch Sicherheitssysteme GmbH...
  • Page 29 VDS-A EN=0/2 Silent Alarm / Chime Mode 0323 VDS-A EN=0/2 Zone Pulse Count 0324 VDS-A EN=0 Zone Lockout 0325 Zone Tamper (DEOL) 0326 Zone Status Report 0327 VDS-A EN=1/5/6/7 Bosch Sicherheitssysteme GmbH Quick Start Guide 2013.07 | 03 | F.01U.267.113...
  • Page 30 Zone Status Report 0357 VDS-A EN=1/5/6/7 Unverified Alarm Report / Cross Zone 0358 VDS-A EN=0 Domestic No. 0359 Zone Function # 15 Address Default Zone Type 0360 - 0361 2013.07 | 03 | F.01U.267.113 Quick Start Guide Bosch Sicherheitssysteme GmbH...
  • Page 31 Key Switch on/off 24 Hour Panic 24 Hour Fire 24 Hour Fire With Verification Tamper Bolt Contact External Fault Delay Exit Interior Delay Exit Technical Alarm Reset Instant Report Reserved Bosch Sicherheitssysteme GmbH Quick Start Guide 2013.07 | 03 | F.01U.267.113...
  • Page 32 Unverified Alarm Report Cross Zone Domestic Call Follow 'Alarm report' Option's Logic. Range 0-7 No Reports Allowed Report to Destination 1 Report to Destination 2 Report to Destination 3 2013.07 | 03 | F.01U.267.113 Quick Start Guide Bosch Sicherheitssysteme GmbH...
  • Page 33 Report to Destination 4 Report to Destination 1 ,2, 3, 4 Report to Destination 1 (2, 3, 4 backup) Report to Destination 1 (2 Backup) and 3 (4 backup) Bosch Sicherheitssysteme GmbH Quick Start Guide 2013.07 | 03 | F.01U.267.113...
  • Page 34 In case of common Area, the Area 1 will be the common Area. When there is only 1 Area in the system, the address 0370 can only be programmed as 1. 2013.07 | 03 | F.01U.267.113 Quick Start Guide Bosch Sicherheitssysteme GmbH...
  • Page 35 For more information, also for multi area system refer to AMAX panel 4000 Installation Manual. Notice! When a zone is assigned to RF Device (3), then the dedicated On-board zone is not available. Bosch Sicherheitssysteme GmbH Quick Start Guide 2013.07 | 03 | F.01U.267.113...
  • Page 36 Zones 25 to 32 are dedicated to DX2010 address 104 ports 1 to 8, also see Table DX2010 modules Notice! When a zone is assigned to Keypad Zone (1) or RF Device (3), then the dedicated zone on DX2010 is not available. 2013.07 | 03 | F.01U.267.113 Quick Start Guide Bosch Sicherheitssysteme GmbH...
  • Page 37 0792 - 0793 0863 0927 0794 - 0795 0864 0928 0796 - 0797 0865 0929 0798 - 0799 0866 0930 0800 - 0801 0867 0931 0802 - 0803 0868 0932 Bosch Sicherheitssysteme GmbH Quick Start Guide 2013.07 | 03 | F.01U.267.113...
  • Page 38: Output Programming

    Output Time 0515 - 0517 VDS-A EN=180 Output 2 Output Event Type 0518 - 0519 VDS-A EN=5 Output Area / Zone 0520 - 0521 Output Mode 0522 VDS-A EN=0 2013.07 | 03 | F.01U.267.113 Quick Start Guide Bosch Sicherheitssysteme GmbH...
  • Page 39 Internal Siren with tamper Entry/Exit Delay Warning 1 - 16 = Areas 1 - 16 Telephone Line Fault AC Power Supply Fault Low Battery Tamper 0 = Any Area, Bosch Sicherheitssysteme GmbH Quick Start Guide 2013.07 | 03 | F.01U.267.113...
  • Page 40 DX3010 module 2 (Output 13 - 20) Table 4.2: DX3010 Address Settings DX3010 1 Output Programming Address 0542 - 0605 See The Value Ranges of Output Programming Options, page 39 2013.07 | 03 | F.01U.267.113 Quick Start Guide Bosch Sicherheitssysteme GmbH...
  • Page 41 0584 - 0585 Output Mode 0586 Output Time 0587 - 0589 Output 11 Address Default Output Event Type 0590 - 0591 Output Area / Zone 0592 - 0593 Output Mode 0594 Bosch Sicherheitssysteme GmbH Quick Start Guide 2013.07 | 03 | F.01U.267.113...
  • Page 42 0632 - 0633 Output Mode 0634 Output Time 0635 - 0637 Output 17 Address Default Output Event Type 0638 - 0639 Output Area / Zone 0640 - 0641 Output Mode 0642 2013.07 | 03 | F.01U.267.113 Quick Start Guide Bosch Sicherheitssysteme GmbH...
  • Page 43: Access Codes

    If the code is set as "15", then code is not used. The code length is the same for all Access Codes. Installer Code Option Address Default Installer Code 1004 1005 1006 1007 1008 1009 Bosch Sicherheitssysteme GmbH Quick Start Guide 2013.07 | 03 | F.01U.267.113...
  • Page 44 1175 - 1180 1181 1182 - 1183 1184 - 1189 1190 1191 - 1192 1193 - 1198 1199 1200 - 1201 1202 - 1207 1208 1209 - 1210 1211 - 1216 2013.07 | 03 | F.01U.267.113 Quick Start Guide Bosch Sicherheitssysteme GmbH...
  • Page 45 1481 - 1486 1487 1488 - 1489 1490 - 1495 1496 1497 - 1498 1499 - 1504 1505 1506 - 1507 1508 - 1513 1514 1515 - 1516 1517 - 1522 Bosch Sicherheitssysteme GmbH Quick Start Guide 2013.07 | 03 | F.01U.267.113...
  • Page 46 1577 1578 - 1579 1580 - 1585 If the code is set as "15", then code is not used. For Code Description refer to User Code Commands, page 8 2013.07 | 03 | F.01U.267.113 Quick Start Guide Bosch Sicherheitssysteme GmbH...
  • Page 47 AMAX panel 4000 / AMAX panel 4000 Configuration | en Value Area Bosch Sicherheitssysteme GmbH Quick Start Guide 2013.07 | 03 | F.01U.267.113...
  • Page 48 AMAX panel 4000 / AMAX panel 4000 en | Configuration 2013.07 | 03 | F.01U.267.113 Quick Start Guide Bosch Sicherheitssysteme GmbH...
  • Page 49: System Programming

    0445 - 0447 0451 - 0453 0457 - 0459 0463 - 0465 0469 - 0471 0475 - 0477 0481 - 0483 0487 - 0489 0493 - 0495 000 - 999 seconds Bosch Sicherheitssysteme GmbH Quick Start Guide 2013.07 | 03 | F.01U.267.113...
  • Page 50 0454 - 0456 0460 - 0462 0466 - 0468 0472 - 0474 0478 - 0480 0484 - 0486 0490 - 0492 0496 - 0498 000 - 999 seconds EN= 045 seconds 2013.07 | 03 | F.01U.267.113 Quick Start Guide Bosch Sicherheitssysteme GmbH...
  • Page 51 Area, no Arming/disarming, bypass and alarm reset operations can be performed on the master keypad. Only by switching the master keypad to the corresponding Area, operations can be performed to the Area. Bosch Sicherheitssysteme GmbH Quick Start Guide 2013.07 | 03 | F.01U.267.113...
  • Page 52 Address 0943 Address Default 0-15 0 = most sensitive 0943 RF Device Low Level Battery Resound Address 0944 Address Default 0 = disable 1 = 4h 2 = 24h 0944 2013.07 | 03 | F.01U.267.113 Quick Start Guide Bosch Sicherheitssysteme GmbH...
  • Page 53 0 = disable 1 = Enable 0945 RF Keyfob Panic Option Address 0946 Address Default 0 = No alarm 1 = Silent alarm 2 = Non silent alarm 0946 Bosch Sicherheitssysteme GmbH Quick Start Guide 2013.07 | 03 | F.01U.267.113...
  • Page 54 2068 2288 1850 – 2070 – 2290 – 1858 2078 2298 1860 – 2080 – 2300 – 1868 2088 2308 1870 – 2090 – 2310 – 1878 2098 2318 2013.07 | 03 | F.01U.267.113 Quick Start Guide Bosch Sicherheitssysteme GmbH...
  • Page 55 1908 2128 1910 – 2130 - 1918 2138 Each RFID Device has nine digits. Each digit range is 0 to 9. The default value is 15, not in use. Bosch Sicherheitssysteme GmbH Quick Start Guide 2013.07 | 03 | F.01U.267.113...
  • Page 56 Wireless Repeater RF ID Repeater Address Default 2340 - 2348 2350 - 2358 2360 - 2368 2370 - 2378 2380 - 2388 2390 - 2398 2400 - 2408 2410 - 2418 2013.07 | 03 | F.01U.267.113 Quick Start Guide Bosch Sicherheitssysteme GmbH...
  • Page 57 2690 – 2698 3010 – 3018 2700 – 2708 3020 – 3028 2710 – 2718 3030 – 3038 2720 – 2728 3040 – 3048 2730 – 2738 3050 – 3058 Bosch Sicherheitssysteme GmbH Quick Start Guide 2013.07 | 03 | F.01U.267.113...
  • Page 58 3350 – 3358 3670 – 3678 3360 – 3368 3680 – 3688 3370 – 3378 3690 – 3698 Assignment of Keyfobs is dynamically done by the System and cannot be changed. 2013.07 | 03 | F.01U.267.113 Quick Start Guide Bosch Sicherheitssysteme GmbH...
  • Page 59 đ Ą Ł Ğ Ć Ś Ű Ş İ Ź Ę ź Ż ᶏ Ń ń Č ł ǧ ¨ ć ś ű č ş ę ţ ż Ț Bosch Sicherheitssysteme GmbH Quick Start Guide 2013.07 | 03 | F.01U.267.113...
  • Page 60 4276 - 4311 4312 - 4347 4348 - 4383 4384 - 4419 4420 - 4455 4456 - 4491 4492 - 4527 4528 - 4563 4564 - 4599 4600 - 4635 2013.07 | 03 | F.01U.267.113 Quick Start Guide Bosch Sicherheitssysteme GmbH...
  • Page 61 5464 - 5499 5500 - 5535 5536 - 5571 5572 - 5607 5608 - 5643 5644 - 5679 5680 - 5715 5716 - 5751 5752 - 5787 5788 - 5823 Bosch Sicherheitssysteme GmbH Quick Start Guide 2013.07 | 03 | F.01U.267.113...
  • Page 62 Zone Name may have up to 18 characters. Each character of the zone name uses 2 addresses. Example: A = 4 1, A = Address 3736 = 4, Address 3737 = 1 2013.07 | 03 | F.01U.267.113 Quick Start Guide Bosch Sicherheitssysteme GmbH...
  • Page 63: Troubleshooting

    No response from the zone – To ensure normal – Operate after 1 minute. for a short time after power operation, the system should be left alone for a minute after power up. Bosch Sicherheitssysteme GmbH Quick Start Guide 2013.07 | 03 | F.01U.267.113...
  • Page 64 Both addresses 0144 – Program the address programming and control. and 0145 are set to 0. 0144 to a number from 1 to 15. Program the address 0145 to 1. 2013.07 | 03 | F.01U.267.113 Quick Start Guide Bosch Sicherheitssysteme GmbH...
  • Page 65 Recommend to set the with ITS- DX4020-G. DX4020-G are not parameter ACK TIMEOUT properly set. of ITS-DX4020-G to the maximum (600) and set TRANSMIT BUFFER LIFE TIME to the maximum (120). Bosch Sicherheitssysteme GmbH Quick Start Guide 2013.07 | 03 | F.01U.267.113...
  • Page 66: Technical Data

    254 EN history events, stamped with time and date – 254 dialer history events, stamped with time and date Pin Code variations: – 1.000.000 Keypads: – DX 3010: – 2013.07 | 03 | F.01U.267.113 Quick Start Guide Bosch Sicherheitssysteme GmbH...
  • Page 67 – Nominal Output Voltage under AC line input: 13,8 VDC +3% / -5% – Output Voltage Range under AC line input: 13.11 VDC to 14.2 VDC – 900mA maximum Bosch Sicherheitssysteme GmbH Quick Start Guide 2013.07 | 03 | F.01U.267.113...
  • Page 68 EN = B, IK = 06, IP = 30 Certification: – EN 50131-3 Grade-3 Environmental Class-II IUI-AMAX3-LED8 (8 Zone LED Keypad) Relative Humidity: – 10%-95% Operating Temperature: – -10°C - +55°C Input Voltage range: – 12V normal 2013.07 | 03 | F.01U.267.113 Quick Start Guide Bosch Sicherheitssysteme GmbH...
  • Page 69 BUS 2 length 700m (max 14 devices, 8 KPs) EN type: – EN = B, IK = 06, IP = 30 Certification: – EN 50131-3 Grade-3 Environmental Class-II Bosch Sicherheitssysteme GmbH Quick Start Guide 2013.07 | 03 | F.01U.267.113...
  • Page 72 Bosch Sicherheitssysteme GmbH Robert-Bosch-Ring 5 85630 Grasbrunn Germany www.boschsecurity.com © Bosch Sicherheitssysteme GmbH, 2013...