IRIS-Net
../PRM/
OUTCHAN
../PRM/LEVEL
../PRM/MODE
../PRM/FREQU
../PRM/MIX
AUDIO_IN
.../PRM/SWITCH AD, AES,
CONTROL OUTPUTS - GPO FUNCTIONS
Two conditions can be programmed for each control output which either activate the output (/CONTROL/OUTx/ON/...)
or deactivate the output (/CONTROL/OUTx/OFF/...). When the assigned function (/CONTROL/OUTx/ON/FNCT or /
CONTROL/OUTx/OFF/FNCT) is recognized as "true" and the state is maintained for at least the set delay or debounce
times (up to 10 sec.), the control output changes to activated (On) or deactivated (Off). The INV parameter allows
inverting the state of the assigned function. Synchronizing the switching of control outputs is possible by means of a
special system-wide CAN command, when SYNC is set to ON. Available functions and corresponding settings are
explained in the following table.
JOB CODES - TRANSMIT FUNCTIONS
Job codes are distributed throughout the CAN network via broadcast command. Each job code has a freely definable
number (ID). Identical conditions can be assigned to job codes and control outputs. A job code with a defined number
(ID) is transmitted, when the corresponding condition for (/JOB/TXx/FNCT) is recognized as "true" and the state is
maintained for at least the set delay or debounce times (up to 10 sec.). The INV parameter allows inverting the state of
the assigned function. Available functions for /JOB/TXx/FNCT/... as well as corresponding parameters /JOB/TXx/
PRM/... are identical to local GPO functions, as outlined in the table.
Function
Parameter
NOTHING
POWER
ABS
../PRM/TYPE
../PRM/CHAN
../PRM/IDX
Bosch Security Systems B.V.
A / B / A,B
Selects output channel A, or output channel B,
or output channel A and B
-128...+50
Defines the testing generator output level
[dBu]
OFF, SINE,
Defines the testing generator's signal type
WHITE, PINK
10...20000
Defines the generator frequency, when SINE is
[Hz]
selected
ON, OFF
Wanted signal and Testing generator signal
mixed
Selection of audio input
Select the analog audio input (AD), the AES/EBU
FLIP
input (AES) order toggles (FLIP) audio input
selection from analog to AED/EBU and vice versa
Range
Description
No function
Interpretation results in "true", when the power amp is
powered on (even during power-on delay) and "false", when
the amp's power is off.
Interpretation results in "true", when the DSP parameter value
is higher or equals the reference value.
IN / OUT
IN selects input channel, OUT selects output channel
A / B /
Selects channel A, or channel B, or channel A and B
A,B
00...FF
Selects the DSP parameter via index number