Bosch IRIS-Net User Manual page 414

Table of Contents

Advertisement

IRIS-Net
PEAK/TEMP-Limiter-Parameter
Element
Default
AMPLIFIER
Default
(39 dB)
THRESHOL
12 Vpk
D AMP
OUTPUT
Bosch Security Systems B.V.
Range
User, Default (39 dB), S900, S1200,
CL800, CL1200, CL1600, CL2000,
LX1600, LX2200, LX3000, L1000
(0dBu), L1000 (+6dBu), L1000
(26dB), L1600 (0dBu), L1600
(+6dBu), L1600 (26dB), L2400
(0dBu), L2400 (+6dBu), L2400
(26dB),
H 2500 (0dBu), H 2500 (32dB), H
2500 (35dB), H 5000 (0dBu), H
5000 (32dB), H 5000 (35dB),
SL900, SL1200, SL1800, SL2400,
DSA8204, DSA8206, DSA8209,
DSA8212, Q44, Q66, CP1200,
CP1800, CP2200, CP3000S,
CP4000S, P1200 (0dBu), P1200
(+6dBu), P1200 (26dB), P2000
(0dBu), P2000 (+6dBu), P2000
(26dB), P3000 (0dBu), P3000
(+6dBu), P3000 (26dB), TG5
(0dBu), TG5 (32dB), TG5 (35dB),
TG7 (0dBu), TG7 (32dB), TG7
(35dB), Q44 MKII, Q66 MKII, Q99,
Q1212, CPS2.4, CPS2.6, CPS2.9,
CPS2.12
Description
If the amplifier type used is not
available in this dropdown, select the
entry „User". Then, select the field and
enter the gain of the amplifier. Please
refer to the technical documentation of
the amplifier or ask your dealer for the
correct gain setting.
THRESHOLD AMP OUTPUT determines
the audio signal level above which the
peak limiter starts operating. Please
refer to the technical documentation of
the used speaker for the power limit
(program power or music power).
then, use the Limiter Threshold
Calculator (Tools > Limiter Threshold
Calculator) to calculate the
corresponding voltage at the amplifier
output.
The Speaker Settings for DYNACORD
or Electro-Voice speakers already
include the correct setting for this
parameter.
User Manual
DIGITAL MATRIX | en
414
2017.05 | 3.20 | F.01U.119.956

Hide quick links: