IRIS-Net
Element
Default
(empty)
(empty)
(empty)
0 ms
Control Outputs: Internal status changes inside of the amplifier, like for example operational faults, alerts when
exceeding parameter limits, and internal operational statuses can be signaled to external systems or central control
units.
Example:
This example shows the programming of two control outputs where OUT1 signals whether the amplifier's power is
switched ON or OFF while OUT2 signals faulty operation.
OUT1 ON: Power (control output 1 is closed when the amplifier's power is switched on)
OUT1 OFF: Invert Power (control output 1 is open when the amplifier's power is switched off / stand-by mode)
OUT2 ON: Errorflag (control output 2 is closed when operational faults according to the parameter list have
occurred)
OUT2 OFF: Invert Errorflag (control output 2 is open when no faults have occurred)
Element
Default
0
Bosch Security Systems B.V.
Range
Description
IN 1 ON
This provides a listing of the two control inputs and their
IN 1 OFF
statuses ON and OFF. The entries in the corresponding lines
IN 2 ON
specify the action when closing (ON) or opening (OFF) a
IN 2 OFF
contact.
This column allows assigning functions to a control input's
statuses. Clicking the desired line in the Function menu
opens a dialog field that shows all accessible functions. The
table "Input and Receive Job Functions" lists all functions
together with their individual settings.
Here you can set the different function parameters. For more
information, please refer to the table "Input and Receive Job
Functions".
Certain functions allow specifying optional parameter values.
0...10027
Here you can program delay or debouncing times. Following
ms
a status change the assigned function is initiated after the
16.33 ms
set time interval has past.
Steps
Range
Description
OUT 1 ON
This provides a listing of the two control outputs and their statuses
OUT 1 OFF
ON and OFF. The entries in the corresponding lines specify which
OUT 2 ON
status results in the closing (ON) or opening (OFF) of a contact.
OUT 2 OFF
User Manual
REMOTE AMPLIFIER | en
2017.05 | 3.20 | F.01U.119.956
114